![Comtech EF Data KST-2000L Installation And Operation Manual Download Page 21](http://html1.mh-extra.com/html/comtech-ef-data/kst-2000l/kst-2000l_installation-and-operation-manual_2648543021.webp)
Chapter 2. Specifications
2.1
Summary of Specifications
Table 2-1. Transmit Specifications
Input Characteristics:
Frequency Range
50 to 90 MHz,
Optional: 100 to 180 MHz
Power Level
Operational: -25 to –45 dBm
Survival: -10 dBm
Connector
Type N, female
Impedance
50
Ω
, unbalanced
VSWR 1.5:1
Output Characteristics:
Frequency Range
14.0 to 14.5 GHz, in 1 MHz steps
Output Power at Flange:
Typical Pso +25
°
C
Guaranteed P1 dBm
2 Watt
33 dBm
32 dBm
4 Watt
36 dBm
35 dBm
Connector WR-75
VSWR 1.5:1
Transfer Characteristics:
Frequency Sense
Non-inverting
System Gain:
(SSG @ 10 dB backoff)
Maximum
Nominal
2 Watt
73 dB
63 dB
4 Watt
76 dB
66 dB
User Attenuator Range
0 to 20 dB, 1 dB steps
Gain Stability over temperature
AGC On, Fixed Frequency
AGC Off, Fixed Frequency
2.0 dB p-p
3.0 dB p-p
Gain variation with frequency:
70
±
20 MHz
140
±
40 MHz
2.0 dB p-p
3.0 dB p-p
2–1