Ku-Band Satellite Transceiver
Revision 9
Terminal Mode Commands
MN/KST2000AB.IOM
B–12
8 Watt SSPAs
Stored Faults
Command
Response
<add/HSF_#’cr’
>add/HSF_#’cr’
RF_yyy’cr’
HPA_xxx’cr’
BV1_xxx’cr’
BV2_xxx’cr’
BV3_xxx’cr’
+9.75V_xxx’cr’
-5V_xxx’cr’
PROG_xxx’cr’’lf’]
SFLT_#’cr’’lf’]
Where: # = 0 to 9
HSF_# NO_FAULT or
RF Output (ON/OFF) Actual Status
HPA Converge Module (OK/FLT)
Bias Voltage #1 (OK/FLT)
Bias Voltage #2 (OK/FLT)
Bias Voltage #3 (OK/FLT)
+9.75 Volt power Supply (OK/FLT)
–5 Volt Power Supply (OK/FLT)
Inter-Processor Communications (OK/FLT)
Number of Stored Faults (# = 0 to 10)
The following response is from an OEM SSPA only:
HPA_xxx’cr’
HPA Converter Module
(OK/FLT)
The following responses are from an OEM TWTA only:
HPA_xxx’cr’
HPA Converter Module
(OK/FLT)
TEMP_xxx’cr’
Temperature (OK/FLT)
HV_xxx’cr’
High Voltage (ON/OFF)
16 Watt SSPAs
Stored Faults
Command
Response
<add/HSF_#’cr’
>add/HSF_#’cr’
RF_yyy’cr’
HPA_xxx’cr’
BV1_xxx’cr’
BV2_xxx’cr’
BV3_xxx’cr’
BV4_xxx’cr’
BV5_xxx’cr’
+9.75V_xxx’cr’
-5V_xxx’cr’
PROG_xxx’cr’
SFLT_#’cr’’lf’]
Where: # = 0 to 9
HSF_# NO_FAULT or
RF Output (ON/OFF) Actual Status
HPA Converge Module (OK/FLT)
Bias Voltage #1 (OK/FLT)
Bias Voltage #2 (OK/FLT)
Bias Voltage #3 (OK/FLT)
Bias Voltage #4 (OK/FLT)
Bias Voltage #5 (OK/FLT)
+9.75 Volt power Supply (OK/FLT)
–5 Volt Power Supply (OK/FLT)
Inter-Processor Communications (OK/FLT)
Number of Stored Faults (# = 0 to 10)
The following response is from an OEM SSPA only:
HPA_xxx’cr’
HPA Converter Module
(OK/FLT)
The following responses are from an OEM TWTA only:
HPA_xxx’cr’
HPA Converter Module
(OK/FLT)
TEMP_xxx’cr’
Temperature (OK/FLT)
HV_xxx’cr’
High Voltage (ON/OFF)
Summary of Contents for KST-2000A
Page 2: ......
Page 28: ...Ku Band Satellite Transceiver Revision 9 Introduction MN KST2000AB IOM 1 14 NOTES ...
Page 102: ...Ku Band Satellite Transceiver Revision 9 Operation MN KST2000AB IOM 5 18 NOTES ...
Page 180: ...Ku Band Satellite Transceiver Revision 9 Glossary MN KST2000AB IOM g 4 NOTES ...