Converter Round Pole Mounting Instructions
1.
Position the converter with fins down and mounting brackets facing upward
(refer to Figure C-3). Position (2) 14” Unistrut channels centered on the
converter mounting brackets. Fasten with
1/4” hardware (4 to 6 each of bolts,
split and flat washers).
Note:
Vary the number and location of the hardware as needed to avoid
interfering with the spring nuts used for the pipe blocks.
Figure C-3. KST-2000A Converter with Mounting Brackets
2.
Position two spring nuts into the channel of one of the remaining Unistrut
channels. With the mounting holes facing the ends of the channel, fasten two
pipe blocks loosely to the spring nuts with the hardware
(2 each 5/16” bolts, split
and flat washers).
3.
Place the channel with pipe blocks against the mounting pole, slide the pipe
blocks until they contact the mounting pole. Ensure the pipe blocks are centered
to the Unistrut and tighten the hardware. Use this channel as a guide and mount
the pipe blocks on the remaining three channels in a similar manner.
Flat fitting plate
Pipe block