Qualifier Meter
1-4
User Preferences
Three built-in features are available for the user to customize the Qualifier meter: the
Country Set, the Unit of Measurement and the selection of six Quick-Tune Measurement
Channels.
One custom user channel line-up set or group can be created and installed to the Qualifier
meter using the Feature Installation Utility. The utility is a PC Windows program necessary
for the customization and installation of a user defined channel set. Digital channel
definitions can only be installed by use of the utility. See section
Feature Installation Utility
for more details.
User Preferences are made available sequentially to the user through the SETUP mode. In
each sequence, the display blinks, showing current settings. Any displayed setting can be
changed with the arrow keys or left alone; changes are saved automatically.
To enter the SETUP mode, press and hold
F6
while powering the unit ON using the
ON/OFF
key.
Automatically, the Qualifier meter activates the
Country Set Define
sequence. The
currently selected Country Set code number blinks. Arrow keys step through the sets
available (see Appendix B for a complete listing). Pressing
F1
leaves this sequence and
initiates the
Units of Measure Define
sequence.
The
Units of Measure Define
sequence of the SETUP mode is indicated by a blinking
Units of Measure
selection. Pressing either the right or left arrow key toggles between
dBmV and dBµV. Pressing
F2
ends this sequence and activates the
Quick-Tune Channels
Define
sequence.
The
Quick-Tune Channels Define
sequence is the final stage of the setup mode.
F1
through
F6
can refer to any six picture/sound carrier pairs contained within the selected
Country Set. At the beginning of the sequence, the channel display blinks, showing the
setting for
F1
. Press any of the six function keys, and the unit displays the current video
carrier channel setting. (If the unit has never been programmed, or if a new Country Set has
been selected in the SETUP mode, the factory preset channel for that function key is
displayed.) Use the arrow keys to change the channel setting if desired. This can be done for
each function key, in any order, and more than once if desired.
End the SETUP mode by pressing
ON/OFF
; this saves the setup and shuts the unit off.