18
Instance #2
Instance #3
Instance #4
Instance #5
CC in #1
IDI0
IDI4
IDI8
IDI12
CC in #2
IDI1
IDI5
IDI9
IDI13
CC in #3
IDI2
IDI6
IDI10
IDI14
CC in #4
IDI3
IDI7
ISI11
IDI15
CC out #1
IDO1
IDO5
IDO9
IDO13
CC out #2
IDO2
IDO6
IDO10
IDO14
CC out #3
ID03
IDO7
IDO11
IDO15
CC out #4
ID04
IDO8
IDO12
IDO16
Inputs are triggered by shorting the respective input to any pin labelled GND. Outputs consist of an open collector
circuit which, when inactive, will offer a high-impedance path to GND and, when active, will offer a low impedance
path to GND. These outputs are capable of sinking up to 200 mA at a voltage up to 40 V. Total sink current for all
outputs is rated at 1.1 A. Do not switch AC mains power using these contacts.
pInouts - serIAl port (InstAnce #1 only)
The
Serial Port
is capable of transferring ancillary data to the far end of the connection. By default, the
communication parameters are set for 9600 bps, no handshaking, no parity, 8 data bits, one stop bit (9600,n,8,1). It
is pinned on a RS-232, 9-pin D female in DCE-style pinning. The port is designed to connect to a 9-pin PC serial port
with a straight-through M-F cable.
Serial Port Pinouts
Pin #
Function
Direction
1
CD
Unused
2
RX Data
From MultiRack
3
TX Data
To MultiRack
4
DTR
To MultiRack
5
Ground
6
DSR
From MultiRack
7
RTS
To MultiRack
8
CTS
From MultiRack
9
RI
Unused
pInouts - serIAl port (InstAnces #2-5)
Serial ports for these instances are available by attaching a USB-Multi Channel Serial adapter to one of the available
USB ports on the rear panel (A USB hub may be required if ports are full). The supported device is the Coolgear
USBG-4X232P1. The additional serial ports are assigned:
Summary of Contents for ACCESS MultiRack
Page 1: ...Product Manual ...
Page 27: ...27 Figure 11 network recovery mode ...