Compu Pool Infinity Series Manual AU
20
10.4 Winterizing the Cell
10.4.1 The Electrolytic Cell will be damaged by freezing water just as your pool plumbing
would. In areas which experience severe or extended periods of freezing
temperatures, be sure to drain all water from the pump, filter, supply and return
lines before any freezing conditions occur. Remove the Cell and store it indoors.
The Power Unit is capable of withstanding winter weather and does not need to be
removed.
10.5 Replacing the Cell
10.5.1 When the titanium blades inside the Electrolytic Cell have reached the end of their
lifespan, replacements are available so that the whole system does not have to be
replaced. Replacements are easily switched out. To ensure quality and value, only
genuine Compu Pool replacement parts may be used.
10.5.2 To remove the cell for replacement turn power to the filter pump and Power Module
off. Disconnect the Cell Cable from the Power Module by turning the locking collar
anti-clockwise. Loosen the two Cell Union Collars and remove the cell.
10.5.3 Replace with the new cell in the opposite manner. There are no changes that need
to be made to the Power Module control settings when replacing the Cell.
11.0 TROUBLESHOOTING
Problem
Possible Cause
Corrective Action
Power LED and
Display Screen not
turning on.
Power not connected to unit.
Check that the Power Module is correctly connected to
a mains outlet and the power is on.
Circuit Breaker Tripped.
Verify input voltage with a voltmeter. If there is input
power, the circuit breaker may have tripped. The
Infinity Series is protected by a 5 amp circuit breaker
located at the base of the Power Module. To reset the
circuit breaker press the small yellow pin back in. Main
power to the unit must be turned off prior to resetting
the circuit breaker. Should the circuit breaker continue
to trip after this exercise then you should consult
Compu Pool for assistance.
Loose ribbon cable between
Power Circuit Board and
Display Circuit Board.
Check that the ribbon cable between the Power Circuit
Board (back) and the Display Circuit Board (front) is
securely connected.
Low or no chlorine
residual.
Insufficient chlorine output %. Increase chlorine production by pressing the "+"
button.
Insufficient running times.
Increase the operating hours of the pool filtration
pump and chlorine generator.