7.2
Wiring
7.2.1
The Power Module comes with a standard 240VAC 10Amp power cable that is to
be connected to mains power. Plug the power cable into a suitable weatherproof
outlet.
7.2.2
Plug the pump power cable into the outlet on the Power Module. The pump outlet is
located on the base of the Power Module. The pump output is rated at 240VAC, 8
Amp max. Check the electrical rating marked on the pump motor, connecting a
pump with a higher amperage rating may result in permanent damage to the Power
Module.
7.3
Installing the Power Module
7.3.1
Mount the Power Module as close to the pump and filtration system as possible.
Make sure the Cell Cable (4.6m) can reach the section of pipe selected for the cell.
Do not install the Power Module within 3 meters of the pool edges.
7.3.2
Using the supplied screws and anchors, secure the Mounting Bracket at eye level
to the wall or support. Once the Mounting Bracket is tightly secured, lift the Power
Module onto the Mounting Bracket and secure with the supplied screws.
7.4
Installing the Cell Module
7.4.1
Be sure the pool pump is turned off.
7.4.2
The Cell is to be fitted into the return line to the pool after the pump, filter and
heater (if applicable). Water flow should come from the filtration system through
the inlet closest to the Cell Cable and out through the opposite outlet.
7.4.3
The orientation of the Cell in the plumbing is critical for the correct function of the
unit. Please refer to Figure 2 for available plumbing configurations.