Compu Pool Infinity Series Manual AU
15
9.3
Control Panel Buttons
9.3.1
1. On / Off.
For normal operation, the system should be left in the “On” state. In this
state the Infinity Unit will produce chlorine according to the desired output %.
Simply press the button again to turn the unit off.
9.3.2
2. OK Button.
Holding this button in for 3 seconds will open the User Menu (see
section 9.5). This button is also used to select settings and cycle through menus.
9.3.3
3. Manual Override.
This button allows you a manual override to control the
system without having to change the unit's settings. When you have finished with
the manual override simply re-press the button to de-activate and return your unit to
its normal settings. Note: When turning the Manual Override function off, the pump
will continue to run for one more minute to flush any residual chlorine from the
plumbing into the pool and the screen will display the word "FLUSHING". If however
Manual Override is turned off within the units set running times, the unit will
continue to operate until the end of its set cycle and the screen will no longer flash
the text "MANUAL OVRD".
9.3.4
4. Salinity Test.
Pressing this button will display the most recent salinity test result
(automatically conducted every hour). One of the following readings will be given:
"Low Salt" - The salinity level is low and salt needs to be added to the pool water.
"Salt OK" - No action is required. "High Salt" - No action is required, the Infinity can
run with high salinity, however very high salinity may be unpleasant to swim in and
may damage other equipment. To perform a real time salinity test, press the LEFT
and RIGHT arrow buttons simultaneously for 3 seconds.
9.3.5
5. Super Chlor.
When you have an abnormally high bather load, a large amount of
rain, a cloudy water condition which needs a large amount of purification to be
introduced, simply press the SUPER
CHLOR button. This electronically “super
chlorinates” the water for 24 hours of physical run time. If the unit is turned off by
pressing the On/Off button or if the SUPER CHLOR button is pressed again, the
unit will return to normal operation. Note: When turning the Super Chlor function off,
the pump will continue to run for one more minute to flush any residual chlorine
from the plumbing into the pool and the screen will display the word "FLUSHING". If
however Super Chlor is turned off within the units set running times, the unit will
continue to operate until the end of its set cycle and the screen will no longer flash
the text "SUPER XX:XX".
9.3.6
6. Winter Mode.
When you are not using your pool during the winter months, it is
advisable to activate the winter mode. Simply press the WINTER MODE button.
The Winter Mode will reduce the output of chlorine to 50% of the set chlorine
output. For example: If chlorine output is set to 80%, it will change to 40% when the
WINTER MODE button is pressed. To deactivate winter mode, simply press the
button again. Note: Reducing the chlorine output during periods when the pool is
not in use will help maximize the life of the cell.