Power Meter
–
POM200
User Manual v1
www.compressedairalliance.com
47
Exception response
Exception response frame format
No.
Alias
Type
Range
(decimal)
Range
(hexadecimal)
Description
1
Salve ID
UInt8
1-247
0x01-0xF7
2
Function code
UInt8
(128+3)
(128+16)
(0x80+0x03)
(0x80+0x10)
3
Exception code
UInt8
4
CRC-16 Check
UInt16
Little-Endian
Exception code of MODBUS
Code
(hexadecimal)
Name
Meaning
0x01
ILLEGAL FUNCTION
The function code received in the query is not
an allowable action for the meter
0x02
ILLEGAL DATA
ADDRESS
The data address received in the query is not
an allowable address for the meter
0x03
ILLEGAL DATA VALUE
A value contained in the query data field is not
an allowable value for the meter
0x04
DEVICE FAILURE
An unrecoverable error occurred while the
server was attempting to perform the
requested action.