v1.0
www.compressedairalliance.com
16
Standard Condensate Drain
User Manual v1
Step 8
Reassemble the valve inner parts and screw the valve back in to the bottom
part of the housing, using a 23mm wrench (max. torque 10 Nm).
Step 9
Close the housing by replacing the electronics compartment and top part on
the reservoir and fixing the 4 housing bolts (max. torque 10 Nm).
Make sure the gaskets are secured properly to ensure IP65 rating and make
sure the electronics have not been in contact with water.
WARNING
: make sure the cable connected to the electronics compartment
does not get damaged while re-assembling the components!
Step 10
Replace the power connector, tighten the connector screw (max. torque 0,3
Nm) and turn on the power supply.
Make sure the gasket is secured properly to ensure IP65 rating.
Make sure the display lights up to check if the power supply is successfully
connected.
Step 11
Slowly open the ball valve to restore the condensate supply.
Step 12
Press and hold down the TEST button to check the valve function.
Your drain is ready for operation!
Note:
Check the drain periodically by pressing the TEST knob. A purging
sound must be heard.