12
ITEM
NAME
FUNCTION
1
RESET
Button / Red Indicator
When lit, indicates that the HT-2000P is unarmed. This button must be pushed before the
TEST
Button is
functional. When the
RESET
Button is pressed, the red
RESET
indicator goes out and the yellow
TEST
indicator is lit.
PRESSING THE RESET BUTTON AT ANY TIME STOPS TEST
.
2
TEST
Button / Yellow
Indicator
When lit, indicates that the HT-2000P is ready to test the connected equipment. The yellow
TEST
indicator
goes out when the
TEST
Button is pressed.
3
Ground OK
/
Ground Open
LED's
Indicates result of Ground test between grounding pin of the line cord and exposed metal parts of the
equipment under test. If the ground circuit has more than three ohms resistance, or if the leads are not properly
connected, the red
Ground Open
LED will light, the internal buzzer will sound, and the test will be
terminated. If the ground circuit resistance is acceptable, the green
Ground OK
LED will light and the test
will continue. If the continuity test is defeated by the operator, both LED's will be lit for the duration of the
test.
4
Excess Leakage
LED
Indicates failure of leakage current test. If leakage current between the primary circuit and ground is higher
than the preset value, the red
Excess Leakage
LED will light, the internal buzzer will sound, and the test will
be terminated.
5
Full Voltage
LED
If full voltage is successfully reached, the green
Full Voltage
LED will light and the high voltage duration
timer starts.
6
Hipot Fail
LED
Indicates failure of high voltage test. If arcing or a flashover of the insulation system between primary parts
and ground is encountered, the red
Hipot Fail
LED will light, the internal buzzer will sound, and the test will
be terminated.
7
Hipot Pass
LED
At the end of the preset high voltage duration time, if no insulation breakdowns are encountered, the green
Hipot Pass
LED will light and the test will terminate
8
Voltage Meter
Provides visual indication to the operator of the actual output voltage of the tester. Used to set the automatic
voltage level during the setup procedure.
9
Ramp Bar Graph LED’s
Individual LED’s light in sequence from left to right as the test voltage ramps from zero to full voltage. LED’s
turn off (ramp back down) at end of test.
10
Return Lead Receptacle
Grounded banana plug receptacle. The 18 AWG Test Return Lead provided is connected here.
11
High Voltage Device
Receptacle
NEMA 5-15R receptacle. For connection of the equipment under test.
Table 2. Controls, Indicators, Connectors - Model HT-2000P Front Panel
Summary of Contents for HT-2000P
Page 2: ......
Page 4: ...2 ...
Page 14: ...11 Figure 2 Controls Indicators Connectors Model HT 2000P Front Panel ...
Page 16: ...13 Figure 3 Controls Indicators Connectors Model HT 2000P Rear Panel ...
Page 18: ...15 ...
Page 26: ...23 ...