8-8
HSZ70 Solutions Software V7.7 for Novell NetWare - PCI
Compaq Confidential – Need to Know Required
Writer:
Robert Young
Project:
HSZ70 Solutions Software V7.7 for Novell NetWare - PCI
Comments:
Part Number:
AA-R8JUE-TE
File Name:
i-ch8 Installing Upgrades to Your RA7000 Subsystem.doc
Last Saved On:
5/22/00 2:23 PM
Preparing and Installing the Second Controller and
Cache Module
The following is a procedure for installing a second controller.
Preparing to Install a Second Controller
Before installing the second controller:
■
Make a serial connection to the installed controller
■
Shutdown the installed controller
Serial Connection
To make a serial connection to the installed see the section, “Accessing the
CLI,” in Chapter 6. Once you have made the serial connection, return to this
section.
Shutting Down the Installed Controller
Shut down the installed controller then the storage enclosure.
To shut down the installed controller:
1.
Connect a maintenance terminal to the existing controller and access the
CLI. (See Chapter 6, “Accessing the CLI.”)
2.
Press Enter to get to a CLI prompt.
3.
At the
HSZ70 >
prompt, type:
HSZ70 > SHOW THIS_CONTROLLER