failed
through 215 - xx:
204 - xx
Address test failed
1. Remove the memory modules one at a
time until the error goes away.
211 - xx
Random pattern test
2. Replace the good modules one at a
failed
time while making sure the error code
does not return.
214 - xx
Noise test failed
3. Replace the bad modules and retest.
215 - xx
Random address test
failed
===========================================================================
Table 2-4. Keyboard Test Error Codes
===========================================================================
Error
Code
Description
Recommended Action
===========================================================================
300 - xx
Failed ID Test
The following steps apply to 300 - xx
through 304 - xx:
301 - xx
Failed Self-test/
Interface Test
1. Check the keyboard connection. If
disconnected, turn off the computer
302 - xx
Failed Individual
and connect the keyboard.
Key Test
2. Replace the keyboard and retest.
3. Replace the system board and retest.
304 - xx
Failed Keyboard
Repeat Test
===========================================================================
Table 2-5. Parallel Printer Test Error Codes
===========================================================================
Error
Code
Description
Recommended Action
===========================================================================
401 - xx
Printer failed or
The following steps apply to 401 - xx
not connected
through 403 - xx:
402 - xx
Failed Port Test
1. Connect the printer.
2. Check power to the printer.
403 - xx
Printer pattern test
3. Install the loop-back connector and
failed
retest.
4. Check switch on the Serial/Parallel
Interface board, if applicable.
5. Replace the Serial/Parallel Interface
board, if applicable.
6. Replace the system board and retest.
===========================================================================
Table 2-6. Diskette Drive Test
===========================================================================
Error
Code
Description
Recommended Action
===========================================================================
600 - xx
Diskette ID drive
The following steps apply to 600 - xx
types test failed
through 698 - xx error codes:
601 - xx
Diskette format
1. Replace the diskette media and retest.
failed
2. Check and/or replace the diskette
power and signal cables and retest.
Summary of Contents for Prolinea 4100
Page 92: ...7 Release the wires going to the power switch from the clamps on the base pan Figure 5 14...
Page 94: ......
Page 95: ......
Page 112: ...8 Remove and retain the hard drive mounting bracket Figure 5 33...
Page 148: ......
Page 150: ......
Page 167: ......
Page 168: ......
Page 191: ...Table A 2 Mouse Pin Signal 1 Data 2 Unused 3 Ground 4 5 VDC 5 Clock 6 Unused...