![Compaq Prolinea 4100 Maintenance & Serice Manual Download Page 25](http://html1.mh-extra.com/html/compaq/prolinea-4100/prolinea-4100_maintenance-and-serice-manual_2645348025.webp)
---------------------------------------------------------------------------
501 - Display
1 Long,
Video display
Replace the video
Adapter Failure
2 Short
controller
board.
---------------------------------------------------------------------------
601 - Diskette
None
Diskette controller
1. Check and/or
Controller Error
circuitry
replace cables.
2. Replace the
system board.
---------------------------------------------------------------------------
602 - Diskette
None
Diskette in drive A
Replace the
Boot
not bootable
diskette.
---------------------------------------------------------------------------
605 - Diskette
2 Short
Mismatch in drive
Run Computer Setup.
Drive Error
type
---------------------------------------------------------------------------
611 - Primary
2 Short
Configuration error
Run Computer Setup.
Floppy Port
Address Assignment
Conflict
---------------------------------------------------------------------------
612 - Secondary
2 Short
Configuration error
Run Computer Setup.
Floppy Port
Address Assignment
Conflict
---------------------------------------------------------------------------
702 - A
None
Configuration error
Run Computer Setup.
Coprocessor Has
Been Detected That
Is Not Reported In
CMOS
---------------------------------------------------------------------------
703 - CMOS Reports
2 Short
Configuration error
Run Computer Setup.
a Coprocessor That
Has Not Been
Detected By POST
---------------------------------------------------------------------------
Message
Beeps
Probable Cause
Recommended Action
---------------------------------------------------------------------------
1151 - COM Port 1
2 Short
Both external and
Run Computer Setup.
Address Assignment
internal serial ports
Conflict
are assigned to COM1
---------------------------------------------------------------------------
1152 - COM Port 2
2 Short
Both external and
Run Computer Setup.
Address Assignment
internal serial ports
Conflict
are assigned to COM2
---------------------------------------------------------------------------
1153 - COM Port 3
2 Short
Both external and
Run Computer Setup.
Address Assignment
internal serial ports
Conflict
are assigned to COM3
---------------------------------------------------------------------------
1154 - COM Port 4
2 Short
Both external and
Run Computer Setup.
Address Assignment
internal serial ports
Conflict
are assigned to COM4
---------------------------------------------------------------------------
1771 - Primary
2 Short
Internal and external
Run Computer Setup.
Disk Port Address
hard drive
Assignment
controllers are both
Conflict
assigned to
Summary of Contents for Prolinea 4100
Page 92: ...7 Release the wires going to the power switch from the clamps on the base pan Figure 5 14...
Page 94: ......
Page 95: ......
Page 112: ...8 Remove and retain the hard drive mounting bracket Figure 5 33...
Page 148: ......
Page 150: ......
Page 167: ......
Page 168: ......
Page 191: ...Table A 2 Mouse Pin Signal 1 Data 2 Unused 3 Ground 4 5 VDC 5 Clock 6 Unused...