POST Error Messages
continued
Code
Meaning
Recommended Action
1787
Slot x Drive Array Operating in Interim
Recovery Mode. The following SCSI drive(s)
should be replaced:
SCSI Port (y): SCSI ID (
x)
Following a system restart, this message
reminds you that drive
x is defective and fault
tolerance is being used. Drive
x needs
replacement as soon as possible. A loose or
defective cable can also cause this error.
1788
1
Slot x Drive Array Reports Incorrect Drive
Replacement. The following SCSI drive(s)
should have been replaced: SCSI Port (y):
SCSI ID (
x).
The following SCSI drive(s) were incorrectly
replaced: SCSI Port (y): SCSI ID (z).
Select
F1
to continue - drive array will
remain disabled.
Select
F2
to reset configuration - all data will
be lost.
The drives indicated were installed in the wrong
place, so they have been disabled. Reinstall the
drives correctly.
Press
F1
to restart the computer with the drive
array disabled. Run ADU for more information.
-Or-
Press
F2
to use the drives as configured and
lose all the data on them.
1789
Slot x Drive Array Physical Drive(s) Not
Responding. Check cables or replace the
following drives: SCSI Port (y):
SCSI ID (x)
Select
F1
to continue - drive array will
remain disabled.
Select
F2
to failed drives that are not
responding - Interim Recovery Mode will be
enabled if configured for fault tolerance.
This message indicates that previously
operating drives are missing or inoperative
following a cold or warm reset. Turn off system
and check cable connections. If cables are
connected, replace the drive. Press
F1
to restart
the computer with the drive array disabled.
-Or-
If you do not want to replace the drives now,
press
F2
.
continued
1
Message 1788 might also be displayed inadvertently due to a bad power cable connection to the drive or a defective SCSI
cable. If this message was due to a bad power cable connection, repair the connection and press F2. If this message is not
eliminated by pressing F2, run the Array Diagnostic Utility.
-OR-
If this message was not due to a bad power cable connection and the drive was not replaced, this could indicate a defective
SCSI cable. Contact your Authorized Compaq Service Provider.