POST Error Messages
continued
Code
Meaning
Recommended Action
1769
Slot x Drive Array - Drive(s) disabled due to
failure during expansion (possibly followed by
one of the following additional details:)
1. Array Accelerator Removed or Failed;
Expansion Progress Data Lost.
2. Expansion Progress Data Could Not Be
Read From Array Accelerator.
3. Expansion Aborted due to Unrecoverable
Drive Errors.
4. Expansion Aborted due to Array Accelerator
Errors.
Press
F1
to continue with logical drives
disabled.
Press
F2
to accept data loss and to re-enable
logical drives.
(RESUME =
F1
OR
F2
KEY)
Data has been lost while expanding the array,
the drives have been temporarily disabled.
Press
F2
to acknowledge the data loss and re-
enable the logical drives. Restore data from
backup. If the Array Accelerator has failed,
replace the Array Accelerator board after the
capacity expansion progress has terminated.
never
turn off the system and replace the Array
Accelerator board if capacity expansion is in
progress.
1774
Slot x Drive Array - Obsolete data found in
Array Accelerator. Data found in accelerator
was older than data found on drives. Obsolete
data has been discarded.
(RESUME =
F1
KEY)
Data found in Array Accelerator is older than
data found on drives, due to drives having been
disconnected, used on another controller, and
then reconnected. Press
F1
to discard older
data.
1775
Slot x Drive Array - ProLiant Storage System
Not Responding SCSI Port (y): Check storage
system power switch and cables. Turn the
system power off while checking the ProLiant
power and cable connections, then turn the
system power back on to retry.
(RESUME =
F1
KEY)
Turn off power to system. Check external
ProLiant power switch. External drives must all
be powered-up before or at the same time as
the main system. Check cables. If retry does not
help, try replacing the cable, ProLiant firmware,
ProLiant backplane, or the Smart Array 3200
Controller.
continued