Chapter 2. Installing the RA8000 and ESA12000
EK–SMCPR–UG. A01
387404–001
2–37
1. Unpack and inspect the contents of the FC hub mounting kit. It should contain the
following components:
Description
Qty.
Mounting Plate Bracket
2
Slide Bracket
2
Rear Mounting Bracket
2
10-32 x 5/8 Pan-Head SEMS Screws
8
Flat Head Screw
4
U-Nut
8
2. Identify the FC hub mounting location.
3. Remove any filler panels from the installation location.
4. Remove all power from the cabinet.
WARNING
HIGH VOLTAGES are present in the cabinet when power is
applied. Failure to disconnect power from the cabinet may
result in personal injury or death.
5. Remove four screws securing the redundant PDU located directly below the
installation area.
6. Pull the redundant PDU outward and route the male plug end of each power cord
under the PDU. Ensure the appropriate number of power cords is routed under the
PDU (one cord per hub),
7. Plug each power cord into the appropriate primary or redundant PDU. For multiple
FC hub configurations, consider labeling each power cord as primary or redundant.
8. Gently push the redundant PDU back into the cabinet and secure the PDU using the
four screws removed in step 5.
CAUTION
Ensure the hub power cords exposed below the PDU are
not pinched and are of sufficient length for connection to the
appropriate FC hub.