RA8000 and ESA12000 Storage Subsystems
2–4
387404–001
EK–SMCPR–UG. A01
NOTE
If you plan to join an expansion cabinet to the master
cabinet, do not lower the levelers at this time.
a) Loosen the locknuts on each leveler foot as shown in Figure 2–4.
b) Turn each leveler hexnut clockwise until the leveler foot contacts the floor.
c) Adjust each leveler foot until the cabinet is level and the load is removed from
all casters. Verify that the casters spin freely.
d) Tighten the locknuts on each leveler foot.
Figure 2–4 Leveler Foot Adjustment
Locknut
Leveler
Hex Nut
Leveler
Foot
SHR-1159
2.2.3 Joining Adjacent ESA12000s
A cabinet joiner and trim kit is included with the ESA12000 expansion cabinet (DS-
SWXES-LA/B or DS-SWXES-TA/B). Use the joiner kit to join two ESA12000 cabinets
together to expand the storage capacity of your subsystem. Refer to the joiner and trim kit
instructions (Joiner Kit Installation Information, Document Part No.: EK–JOINR–IN.
D01) supplied with the cabinet.
After two cabinets have been joined, refer to Section 2.4.7 of this guide for cabling
instructions describing how to connect the components in the master cabinet to the
components in the expansion cabinet.