![Compaq Deskpro 386 - Desktop PC Maintenance And Service Manual Download Page 117](http://html.mh-extra.com/html/compaq/deskpro-386-desktop-pc/deskpro-386-desktop-pc_maintenance-and-service-manual_2645689117.webp)
Maintenance and Service Guide
5-25
Addendum 108431-001 (11-88) to
Manual No. 108033-003
Table 5-2. Advanced Diagnostics Error Codes
Continued
Error
Code
Description
Recommended
Action
-xx
The following steps apply to error codes 1700-xx
through 1799-xx:
1. Run SETUP.
2. Check the switch settings and jumper positions on the
controller board and retest (see
Chapter 8
).
3. Replace the fixed disk drive signal and power cables
and retest.
4. Replace the controller board and retest.
5. Replace the fixed disk drive and retest.
6. Replace the system board and retest.
61
Failed uncorrectable ECC* error.
62
Failed correctable ECC* error.
63
Failed soft error rate.
65
Exceeded maximum bad sector
per track.
66
Failed initial drive parameter.
67
Failed to write long.
68
Failed to read long.
69
Failed to read drive size
from controller.
70
Failed translate mode.
71
Failed nontranslated mode.
72
Bad track limit exceeded.
73
Previously exceeded bad track limit.
*Error Correction Code
Continued...
Summary of Contents for Deskpro 386 - Desktop PC
Page 1: ...COMPAQ DESKPRO 386 Personal Computer MAINTENANCE AND SERVICE GUIDE ...
Page 2: ......
Page 16: ......
Page 24: ......
Page 26: ......
Page 46: ......
Page 48: ......
Page 58: ......
Page 90: ......
Page 92: ......
Page 130: ......
Page 132: ......
Page 156: ......
Page 254: ......
Page 256: ......
Page 276: ......