Table 5-2. Advanced Diagnostics Error Codes
Continued
Error
Code
Description
Recommended
Action
Serial Test
1101-01
Serial Port Test, UART DLAB bit failure.
The following steps apply to error codes 1101-xx
through 1109-xx.
1. Check the switch settings and jumper positions on
the multipurpose fixed disk controller board (see
Chapter 8
).
2. Replace the multipurpose fixed disk drive controller
board and retest.
3. Replace the system board and retest.
1101-02
Serial Port Test, line input or UART fault.
1101-03
Serial Port Test, address line fault.
1101-04
Serial Port Test, data line fault.
1101-05
Serial Port Test, UART
control signal failure.
1101-06
Serial Port Test, UART THRE bit failure.
1101-07
Serial Port Test, UART DATA READY
bit failure.
1101-08
Serial Port Test, UART TX/RX
buffer failure.
1101-09
Serial Port Test, INTERRUPT
circuit failure.
1101-10
Serial Port Test, COM-1 set to
invalid interrupt.
1101-11
Serial Port Test, COM-2 set to
invalid interrupt.
1101-12
Serial Port Test, DRIVER/RECEIVER
control signal failure.
1101-13
Serial Port Test, UART control signal
interrupt failure.
Continued...
Summary of Contents for Deskpro 386 - Desktop PC
Page 1: ...COMPAQ DESKPRO 386 Personal Computer MAINTENANCE AND SERVICE GUIDE ...
Page 2: ......
Page 16: ......
Page 24: ......
Page 26: ......
Page 46: ......
Page 48: ......
Page 58: ......
Page 90: ......
Page 92: ......
Page 130: ......
Page 132: ......
Page 156: ......
Page 254: ......
Page 256: ......
Page 276: ......