5-24
Chapter 5, Error Messages and Codes
Addendum 108431-001 (11-88) to
Manual No. 108033-003
Table 5-2. Advanced Diagnostics Error Codes
Continued
Error
Code
Description
Recommended
Action
-xx
The following steps apply to error codes 1700-xx
through 1799-xx:
1. Run SETUP.
2. Check the switch settings and jumper positions on the
controller board and retest (see
Chapter 8
).
3. Replace the fixed disk drive signal and power cables
and retest.
4. Replace the controller board and retest.
5. Replace the fixed disk drive and retest.
6. Replace the system board and retest.
45
Failed to get drive parameters
from ROM.
46
Invalid drive parameters found
in ROM.
47
Failed to park heads.
48
Failed to move disk table to RAM.
49
Failed to read media in file write test.
50
Failed file I/O write test.
51
Failed file I/O read test.
52
Failed file I/O compare test.
53
Failed drive/head register test.
54
Failed digital input register test.
55
Failed cylinder 1.
56
Fixed disk drive controller RAM diag-
nostics failed.
57
Fixed disk drive controller to drive
test failed.
58
Failed to write sector buffer.
59
Failed to read sector buffer.
60
Failed to compare sector buffer.
Continued...
Summary of Contents for Deskpro 386 - Desktop PC
Page 1: ...COMPAQ DESKPRO 386 Personal Computer MAINTENANCE AND SERVICE GUIDE ...
Page 2: ......
Page 16: ......
Page 24: ......
Page 26: ......
Page 46: ......
Page 48: ......
Page 58: ......
Page 90: ......
Page 92: ......
Page 130: ......
Page 132: ......
Page 156: ......
Page 254: ......
Page 256: ......
Page 276: ......