1-2
Removal and Replacement Procedures
1.2
Service Considerations
Listed below are some of the considerations that you should keep in mind during the disassembly
and assembly of the Compaq Aero 8000 H/PC Pro.
1.2.1
Tool and Software Requirements
To service the Aero 8000, you need the following:
„
#
Magnetic screwdriver
„
#
Torx T-8 screwdriver
„
#
Small Phillips or flat blade screwdriver
1.2.2
Screws
The screws used in the Compaq Aero 8000 H/PC Pro are not interchangeable. If an incorrect screw
is used during the reassembly process, it can damage the unit. Compaq strongly recommends that all
screws removed during disassembly be kept with the part that was removed, then returned to their
proper locations.
CAUTION:
When servicing the computer, ensure that all screws are kept with the part with
which they belong. Using an improper screw during reassembly can damage the computer.
IMPORTANT:
As each subassembly is removed from the computer, it should be placed away from the
work area to prevent damage.
1.2.3
Cables and Connectors
Cables must be handled with extreme care to avoid damage. Apply only the tension required to seat
or unseat the cables during insertion or removal from the connector. Handle cables by the connector
whenever possible. In all cases, avoid bending, twisting. Or tearing the cables, and ensure that the
cables are routed in such a way that they cannot be caught or snagged by parts being removed or
replaced. Handle flex cables with extreme care; they can tear easily.
CAUTION:
When servicing the computer, ensure that cables are placed in their proper
location during the reassembly process. Improper cable placement can damage the
computer.
1.2.4
Plastic Parts
Plastic parts can be damaged by the use of excessive force during disassembly and reassembly.
When handling the plastic parts, use care. Use a bezel removal tool to separate plastic components.
Apply pressure only at the points designated in the maintenance instructions.