background image

HYDRAULIC CONNECTIONS FOR TWO LINE STEERING SYSTEMS

 

 

A simple schematic of the pump installation is shown in Figure 2. 

 

2 Line Steering System Installation 

 
 
Delivery Lines: 
  Ports A and B in the diagram above are 

the input/output ports of the pump and 
must be connected to the steering lines 
coming from the steering cylinder. It does 
not matter which pump port is connected 
to which steering line. 

 
 
Compensating Line: 
  In the above diagram Port C is the 

compensating or bleed line, and must be 
connected to the steering system's 
reservoir. This connection can be made 
at a helm pump, remote reservoir (if there 
is one), the compensating line connecting 
two helm pumps, or the compensating 
line connecting a helm pump to the 
remote reservoir. If the connection is 
being made directly to the helm pump, 
ensure that the bleed line is connected to 
the 

LOWER

 helm bleed port.  

 
The compensating line MUST have a gradual rise from the pump to the connection to the 
steering system. This allows air to rise out of the pump, ensuring a constant supply of oil to the 
pump.  
 
 
 

 
29010015V1.0(15CI & 25CI Pumps).doc 

4

Summary of Contents for 15CI

Page 1: ...phone 604 207 1600 Fax 604 207 8008 In Canda or the U S A Toll Free Phone 1 800 428 0212 Toll Free Fax 1 800 470 9611 15CI and 25CI Reversing Motor Pumpset Owner s Manual Part Numbers 20810009 2081001...

Page 2: ...3 line steering installation instructions carefully TOOLS AND MATERIAL REQUIRED TO INSTALL PUMP 1 Basic Tool Kit 2 Pipe Cutter 3 Funnel with Filter a coffee filter will do 4 3 8 Electrical Drill 5 2...

Page 3: ...ing system The first is to leave the system completely filled and be careful not to spill hydraulic fluid The second is to drain the system of fluid completely before cutting or opening any lines If y...

Page 4: ...per tube Wipe the filings off instead Do not use a tape type thread sealer These can shred and enter the steering system fluid A teflon based thread sealer such as LOCTITE P S T must be used on all ma...

Page 5: ...is the compensating or bleed line and must be connected to the steering system s reservoir This connection can be made at a helm pump remote reservoir if there is one the compensating line connecting...

Page 6: ...ensating or bleed line and must be connected to the steering systems reservoir This connection can be made at a helm pump a remote reservoir if there is one the return line connecting two helm pumps o...

Page 7: ...bic cm Current at 200 PSI 13 8 kg square cm 3 3 Amps Part No 20810027 Operating Voltage 24 VDC Displacement at 200 PSI 95 Cubic Inches 1556 cubic cm Current at 200 PSI 13 8 kg square cm 4 5 Amps ALL P...

Page 8: ...L CONNECTIONS Reversing Pump connections to ComNav CT2T Motor Control Box Typically used on 1001 1101 1201 and 2001 Autopilots Reversing Pump connections to ComNav Processor type Autopilots 29010015V1...

Page 9: ...eed the Reversing Pump you will be extending the cylinder rod in the other direction Open one and close the other bleeding screw just as you did when bleeding the manual part of your system and you we...

Page 10: ...Bleeding cylinder rod moving left Bleeding cylinder rod moving right 29010015V1 0 15CI 25CI Pumps doc 9...

Page 11: ...pment a short distance from the cylinders and fittings 14 Use the Autopilot to extend the rod fully in one direction and then the other 15 Check for leaks by looking for spilled hydraulic fluid near o...