REFILL AND BLEED
After you have installed your Pump, refill and bleed your manual steering system according to
the manufacturer's directions. Air which is in the Pump will be expelled in a seperate bleeding
routine after you connect the Pump to the autopilot.
SPECIFICATIONS
Part No. 20810009
Operating Voltage
- 12 VDC
Displacement at 200 PSI
- 60 Cubic Inches (982 cubic cm.) per Minute
Current at 200 PSI (13.8 kg/square cm.) - 6.5 Amps
Part No. 20810011
Operating Voltage
- 12 VDC
Displacement at 200 PSI
- 95 Cubic Inches (1556 cubic cm.) per Minute
Current at 200 PSI (13.8 kg/square cm.) - 9.0 Amps
Part No. 20810026
Operating
Voltage
-
24
VDC
Displacement at 200 PSI
- 60 Cubic Inches (982 cubic cm.)
Current at 200 PSI (13.8 kg/square cm.) - 3.3 Amps
Part No. 20810027
Operating
Voltage
-
24
VDC
Displacement at 200 PSI
- 95 Cubic Inches (1556 cubic cm.)
Current at 200 PSI (13.8 kg/square cm.) - 4.5 Amps
ALL PUMPS
Port Size
- 1/4 Inch NPT, all ports
Max. Continuous Operating Pressure
- 300 PSI (20.8 kg/square cm.)
Max. Continuous Current Draw
- 12 Amps (12 VDC Models)
Minimum Stall Pressure (no flow)
- 650 PSI (45.0 kg/square cm.)
Oil Type/Viscosity Range
- Any approved hydraulic steering fluid
Operating Temperature Range
- 0 to 50 Degrees Centigrade
Lockvalve
Leakage
-
None
Unbalanced Cylinder Size
- Up to 3/4 Inch (1.9 cm.) Diameter Rod
Weight
- maximum 5 Pounds, (2.27 kg) including wire.
Size
- 7.5 Inches Long x 5 Inches Wide x 4 Inches
High (19.1 cm. x 12.5 cm. x 10.16 cm.)
Shaft Seal
- Long Life, Dual-Lip Spring Loaded Seal, Can
Hold Tank Pressures of 60 PSI. (4.1 kg/sq.cm.)
29010015V1.0(15CI & 25CI Pumps).doc
6