4. Commissioning
M0200AKA_uc_ION-U_EU_L_25T_25T.docx
User’s Manual for ION
®
-U Page
35
4.2. Low Power EU Electrical Installation
4.2.1. Health and Safety for electrical installation
Read and observe chapter 1.2 Health and Safety.
1. Danger: Electrical hazard. Danger of death or fatal injury from electrical
current. Obey all general and regional installation and safety regulations
relating to work on high voltage installations, as well as regulations covering
correct use of tools and personal protective equipment.
2. Danger: Electrical hazard. Danger of death or fatal injury from electrical
current inside the unit in operation. Before opening the unit, disconnect
mains power.
4.2.2. Property Damage Warnings for electrical installation
1.
Attention:
It is compulsory to ground (earth) the unit before connecting the power
supply. Grounding bolts are provided on the cabinet to connect the ground-bonding
cable.
2.
Attention:
If the mains connector of the unit is not easily accessible, a disconnect
device in the mains power circuit must be provided within easy reach.
3.
Attention:
A connection of the mains supply to a power socket requires the power
socket to be nearby the unit.
4.
Attention:
Before connecting or disconnecting the mains connector at the unit,
ensure that mains power supply is disconnected.
5.
Attention:
Make sure that an appropriate circuit breaker acting as a disconnect
device (as required by IEC/EN60950-1) and an overcurrent limiting device are
connected between mains power and the unit.
6.
Attention:
Incorrectly wired
connections
can destroy electrical and electronic
components.
7.
Notice:
Although the unit is internally protected against overvoltage, it is strongly
recommended to ground (earth) the antenna cables close to the antenna
connectors of the unit for protection against atmospheric discharge. In areas with
strong lightning, it is strongly recommended to install additional lightning
protection.
8.
Notice:
To avoid corrosion at the connectors caused by electrochemical
processes, the material of the cable connectors must not cause a higher potential
difference than 0.6 V (see electrochemical contact series).