5. Low Power EU Maintenance
Page 54
M0200AKA_uc_ION-U_EU_L_25T_25T.docx
User’s Manual for ION
®
-U
5.2. EU Power Supply Replacement
The power supply for the EU is a field replaceable module. The type of power supply
used by the unit (AC, DC, or Vdc/100) is dependent on the model number.
Attention:
Before starting any maintenance on the EU, read and observe
chapter 1.2
Health and Safety and the electrical installation information in chapter 4.2.1 Health
and Safety for electrical installation.
1. Danger: Electrical hazard. Danger of death or fatal injury from electrical
current inside the unit in operation. Before opening the unit, disconnect
mains power.
2. Caution: The unit reaches high temperature in operation. Risk of burns by
hot surface. Do not touch the unit before it has sufficiently cooled down.
1.
Switch off the circuit breaker
supplying power to the EU.
2.
Once you have confirmed that
the power has been shutdown,
remove Mains power
connector from the unit.
figure 5-1 Disconnect mains power
3. Locate the power supply on the
right side of the Extension Unit.
Mains plug
Power
supply
Summary of Contents for ION-U EU L 25T/25T
Page 1: ...ION U ION U EU L 25T 25T User s Manual M0200AKA ...
Page 62: ......