4.1.35 Apply one layer of foam tape around the IF-cable, at the end
of the jacket. This tape prevents easy pull-out of the cable.
4.1.36 Feed the IFC through the horn.
4.1.40 Make sure the transition of secondary to primary coating is
in the splice protector. If this is not possible: strip the secondary coating
(semi-tight) in the middle of the groove plate.
4.1.39 In case of single circuit tray (SC): 2 fibers can be terminated.
The following positions should be used on the metal bracket:
1, 2, 4, 5, 7, 8, 10, 11.
In case of single circuit (SC trays) with 4 semi-tight fibers per tray,
use all the bracket positions and remove the secondary coating in the
middle of the groove plate. Do not use (= leave empty) trays number
4, 8, 12, 16.
4.1.38 In case of Single Element cassettes (SE): 6 fibers can be
terminated per tray.
4.1.37 Fasten the cable onto the bracket with the tie-wraps. Don’t
squeeze the cable !!! For ease of installation start at the left.
4.2
Side cable termination directly on the shelf
a) Loose tube cable