background image

                                                                          

 

 COMM-TEC Germany                                       www.comm-tec.de

 

 

UP-1200 Presentation Switcher/Scaler  
 

MASTER VOL  

With this rotary knob you can adjust the amplifier 
output between -20dB and +8 dB in steps of 0.5dB. 

 

9. 

AUDIO INPUTS 

 

The UP-1200 offers 9 unbalanced audio inputs, 
wherein AUDIO INPUTS 1-4 correspond to the analog 
video sources as follows: 
 
AUDIO INPUT 1 

 CV video signal. 

AUDIO INPUT 2 

 YPbPr video signal 

AUDIO INPUT 3 

 VGA1 video signal 

AUDIO INPUT 4 

 VGA2 video signal 

 
The audio inputs 5-9 are not assigned and can be 
combined with any video source. 
 

VIDEO INPUTS——1 CVBS, 1 component video 
YPbPr,2 VGA,3 HDMI,1 DisplayPort,1 HDBaseT 
input. 

DisplayPort audio interface input signal can 

not be output from the amplifier balanced audio 
interface. 
 

10. 

AMPLIFIER OUTPUT ——1 amplifier 

balanced audio output

 

 

11. 

VIDEO OUTPUT——1 HDMI, 1 HDBaseT 

output; 

Wherein when the CV, YPbPr, VGA1,VGA2 video 
input interface and AUDIO INPUTS 1~4 audio 
interface have access to signals: 
AUDIO INPUTS 1 and CV signal default fixed 
synthesis HDIM output. 
AUDIO INPUTS 2 and YPbPr signal default fixed 
synthesis HDIM output. 
AUDIO INPUTS 3 and VGA1 signal default fixed  
 
synthesis HDIM output. 
AUDIO INPUTS 4 and VGA2 signal default fixed 
synthesis HDIM output. 
 

12. 

CONTROL——signal control 

district

 

RS-232——

RS-232 control port, with the 

baud rate of 115200,is to connect a 
computer or other equipment with RS232 
control interface to achieve the goal of 
controlling the device. 

ETHERNET——

Ethernet control port can 

get into the internet to achieve the goal of 
controlling the device. 

 

13. 

Ground column 

 

14. 

System power input port

 

Controller power input,support AC100~240V 
50/60Hz. 

 

2.2  Interface description 

2.2.1  COM port description 

The UP-1200 switching scaler can be 
controlled via RS-232 or via Ethernet. 

 

COM port pin description is as follows: 

Pin-out  signal 

description 

TXD  Sending data 

RXD  Receiving data 

GND  Signal ground 

 

 

 

 

 

 

Summary of Contents for UP-1200

Page 1: ...Switching Scaler Version 1 1 Operating Instructions Thank you for purchasing our product Please be sure to read this instruction manual carefully before using our product UP 1200 Operating instructio...

Page 2: ...insulation occurring within the equipment may cause people suffer from shock CE certification means that the product has reached the directive safety requirements defined by the European Union Users...

Page 3: ...g Only after cutting down all external power source can install wiring operation begin or it may cause electric shock or equipment damage This product grounds by the grounding wires To avoid electric...

Page 4: ...ion 3 2 2 RJ45 network cable producing methods 4 2 3 Diagram of system connection 5 2 4 Panel operating instructions 5 2 4 1 LCD display 5 2 4 2 Button lights 5 2 4 3 Operation introduction 5 2 4 4 Op...

Page 5: ...ontrol Therefor the UP 1200 can be widely used in broadcast environments conference rooms education facilities command and control centers and other occasions 1 1 Features Supports 9 video signal inpu...

Page 6: ...if you switch between the inputs audio follows video But you can manually select a different audio source audio breakaway for a video source By pressing the AV button you can manually select an audio...

Page 7: ...VGA1 VGA2 video input interface and AUDIO INPUTS 1 4 audio interface have access to signals AUDIO INPUTS 1 and CV signal default fixed synthesis HDIM output AUDIO INPUTS 2 and YPbPr signal default fi...

Page 8: ...ked with different colors There are two methods of twisted pair connection EIA TIA 568B standard and EIA TIA 568A standard T568A line order 1 2 3 4 5 6 7 8 White and green green White and orange blue...

Page 9: ...l light up red You can setup the device by pressing the button MENU Menu operation steps can be summarized as Enter the menu choose option with parameter knob select option with ENTER button change pa...

Page 10: ...desired setting then press ENTER Step three Turn the PARAMETER knob to change the desired parameter then press ENTER to confirm the selection Step four Press the MENU to return to the previous menu If...

Page 11: ...just option 7 Press ENTER to enter the option parameter settings The LCD shows the current brightness value Use the PARAMETER knob to set the brightness value to 60 8 Press ENTER to confirm the change...

Page 12: ...COMM TEC Germany www comm tec de 8 COMM TEC UP 1200 Switching Scaler Manual...

Page 13: ...OMM TEC UP 1200 Switching Scaler Manual 2 5 Menu structure VGA Adjust is only valid when a VGA source has been connected to the UP 1200 COPY TO HDMI in EDID menu is only valid when a sink has been con...

Page 14: ...g Scaler Manual Chapter Three Control Codes RS232 communication RS232 communications settings Baud rate 115200 configurable Data bits 8 Parity None Stop bits 1 Flow control None TCP IP communication T...

Page 15: ...n S AUDIO 0 AUDIO 1 INPUT Select the AUDIO 1 INPUT S AUDIO 1 AUDIO 2 INPUT Select the AUDIO 2 INPUT S AUDIO 2 AUDIO 3 INPUT Select the AUDIO 3 INPUT S AUDIO 3 AUDIO 4 INPUT Select the AUDIO 4 INPUT S...

Page 16: ...Response Description S OUTPUT 0 OUTPUT 640x480 60Hz Set output resolution to 640x480 60Hz S OUTPUT 1 OUTPUT 800x600 60Hz Set output resolution to 800x600 60Hz S OUTPUT 2 OUTPUT 1024x768 60Hz Set outp...

Page 17: ...9 it means that the audio input are the embedded audio signals of the digital inputs HDMI1 HMDI2 HDMI3 and HDBaseT For example For adjust the second audio input to 12dB the corresponding command is A...

Page 18: ...ut H Start 1 Move the VGA input image one column right HTotal VGA Input H Total 1 Add 1 column to the total of VGA input images HTotal VGA Input H Total 1 Remove 1 column of the total of VGA input ima...

Page 19: ...AR 192 168 1 1 Set the gateway SUBR 255 255 255 0 SUBR 255 255 255 0 Set the subnet mask SPORT 6666 SPORT 6666 Set connection port number SIPR SIPR 192 168 1 190 Get the IP address GAR GAR 192 168 1 1...

Page 20: ...2 25 Gbps lane Interface HDMI A interface Type A connector 3 HDMI input 1HDMI output Minimum maximum level T M D S 2 9V 3 3V Input EDID Use the system default EDID supports EDID mapping to the input R...

Page 21: ...Noise 0 05 1 kHz with rated voltage Signal to Noise S N 80dB Stereo separation 80dB 1 kHz Signal type stereo Impedance input 10 k unbalanced maximum input level 19 5dBu Control types Front panel Illu...

Reviews: