Important note                         

 Warning 

In  order  to  ensure  the  reliable  performance  of 
the equipment and the safety of the user, please 
observe the following matters during the process 
of installation, use and maintenance: 

The matters needing attention of installation  

◆ Please do not use this product in the following 
places:the  place  of  dust,soot  and  electric 
conductivity  dust,  corrosive  gas,  combustible 
gas;  the  place  exposed  to  high  temperature, 
condensation,wind  and  rain;  the  occasion  of 
vibration and impact . Electric shock, fire, wrong 
operation can lead to damage and deterioration 
to the product, either;  
◆In  processing  the  screw  holes  and  wiring, 
make sure that metal scraps and wire head will 
not  fall  into  the  shaft  of  controller,  as  it  could 
cause a fire, fault, or incorrect operation; 
◆When the installation work is over, it should be 
assured  there  is  nothing  on  the  ventilated  face, 
including  packaging  items  like  dust  paper. 
Otherwise  this  may  cause  a  fire,  fault,  incorrect 
operation for the cooling is not free; 
◆Should avoid wiring and inserting cable plug in 
charged state, otherwise it is easy to cause the 
shock, or electrical damage;  
◆The  installation  and  wiring  should  be  strong 
and  reliable,contact  undesirable  may  lead  to 
false action;  
◆For  a  serious  interference  in  applications, 
should  choose  shield  cable  as  the  high 
frequency  signal input  or  output  cable,  so  as  to 
improve the anti-jamming ability of the system.  

Attention in the wiring  

◆Only  after  cutting  down  all  external  power 
source,  can  install,  wiring  operation  begin,  or  it 
may cause electric shock or equipment damage; 
◆This  product  grounds  by  the  grounding 
wires .To avoid electric shocks, grounding wires 
and  the  earth  must  be  linked  together.  Before 
the  

 

 

 
connection  of  input  or  output  terminal,  please 
make sure this product is correctly grounded; 
◆Immediately  remove  all  other  things  after  the 
wiring installation. Please cover the terminals of 
the products cover before electrification so as to 
avoid cause electric shock. 

Matters  needing  attention  during  operation 
and maintenance 

◆Please  do  not  touch  terminals  in  a  current 
state,or  it  may  cause  a  shock,  incorrect 
operation;  
◆Please  do  cleaning  and  terminal  tighten  work 
after  turning  off  the  power  supply.  These 
operations can lead to electric shock in a current 
state;  
◆Please do the connection or dismantle work of 
the communication signal cable , the expansion 
module  cable  or  control  unit  cable  after  turning 
off the power supply, or it may cause damage to 
the equipment, incorrect operation; 
◆Please do not dismantle the equipment, avoid 
damaging the internal electrical component; 
◆Should  be  sure  to  read  the  manual,  fully 
confirm  the  safety,  only  after  that  can  do 
program  changes,commissioning,start  and  stop 
operation; 

Matters  needing  attention  in  discarding 
product  

◆Electrolytic explosion:the burning of electrolytic 
capacitor  on  circuit  boards  may  lead  to 
explosion;  
◆Please  collect  and  process  according  to  the 
classification, do not put into life garbage; 
◆Please  process  it  as  industrial  waste,  or 
according  to  the  local  environmental  protection 
regulations. 
 

 

 

Summary of Contents for UP-1200

Page 1: ...Switching Scaler Version 1 1 Operating Instructions Thank you for purchasing our product Please be sure to read this instruction manual carefully before using our product UP 1200 Operating instructio...

Page 2: ...insulation occurring within the equipment may cause people suffer from shock CE certification means that the product has reached the directive safety requirements defined by the European Union Users...

Page 3: ...g Only after cutting down all external power source can install wiring operation begin or it may cause electric shock or equipment damage This product grounds by the grounding wires To avoid electric...

Page 4: ...ion 3 2 2 RJ45 network cable producing methods 4 2 3 Diagram of system connection 5 2 4 Panel operating instructions 5 2 4 1 LCD display 5 2 4 2 Button lights 5 2 4 3 Operation introduction 5 2 4 4 Op...

Page 5: ...ontrol Therefor the UP 1200 can be widely used in broadcast environments conference rooms education facilities command and control centers and other occasions 1 1 Features Supports 9 video signal inpu...

Page 6: ...if you switch between the inputs audio follows video But you can manually select a different audio source audio breakaway for a video source By pressing the AV button you can manually select an audio...

Page 7: ...VGA1 VGA2 video input interface and AUDIO INPUTS 1 4 audio interface have access to signals AUDIO INPUTS 1 and CV signal default fixed synthesis HDIM output AUDIO INPUTS 2 and YPbPr signal default fi...

Page 8: ...ked with different colors There are two methods of twisted pair connection EIA TIA 568B standard and EIA TIA 568A standard T568A line order 1 2 3 4 5 6 7 8 White and green green White and orange blue...

Page 9: ...l light up red You can setup the device by pressing the button MENU Menu operation steps can be summarized as Enter the menu choose option with parameter knob select option with ENTER button change pa...

Page 10: ...desired setting then press ENTER Step three Turn the PARAMETER knob to change the desired parameter then press ENTER to confirm the selection Step four Press the MENU to return to the previous menu If...

Page 11: ...just option 7 Press ENTER to enter the option parameter settings The LCD shows the current brightness value Use the PARAMETER knob to set the brightness value to 60 8 Press ENTER to confirm the change...

Page 12: ...COMM TEC Germany www comm tec de 8 COMM TEC UP 1200 Switching Scaler Manual...

Page 13: ...OMM TEC UP 1200 Switching Scaler Manual 2 5 Menu structure VGA Adjust is only valid when a VGA source has been connected to the UP 1200 COPY TO HDMI in EDID menu is only valid when a sink has been con...

Page 14: ...g Scaler Manual Chapter Three Control Codes RS232 communication RS232 communications settings Baud rate 115200 configurable Data bits 8 Parity None Stop bits 1 Flow control None TCP IP communication T...

Page 15: ...n S AUDIO 0 AUDIO 1 INPUT Select the AUDIO 1 INPUT S AUDIO 1 AUDIO 2 INPUT Select the AUDIO 2 INPUT S AUDIO 2 AUDIO 3 INPUT Select the AUDIO 3 INPUT S AUDIO 3 AUDIO 4 INPUT Select the AUDIO 4 INPUT S...

Page 16: ...Response Description S OUTPUT 0 OUTPUT 640x480 60Hz Set output resolution to 640x480 60Hz S OUTPUT 1 OUTPUT 800x600 60Hz Set output resolution to 800x600 60Hz S OUTPUT 2 OUTPUT 1024x768 60Hz Set outp...

Page 17: ...9 it means that the audio input are the embedded audio signals of the digital inputs HDMI1 HMDI2 HDMI3 and HDBaseT For example For adjust the second audio input to 12dB the corresponding command is A...

Page 18: ...ut H Start 1 Move the VGA input image one column right HTotal VGA Input H Total 1 Add 1 column to the total of VGA input images HTotal VGA Input H Total 1 Remove 1 column of the total of VGA input ima...

Page 19: ...AR 192 168 1 1 Set the gateway SUBR 255 255 255 0 SUBR 255 255 255 0 Set the subnet mask SPORT 6666 SPORT 6666 Set connection port number SIPR SIPR 192 168 1 190 Get the IP address GAR GAR 192 168 1 1...

Page 20: ...2 25 Gbps lane Interface HDMI A interface Type A connector 3 HDMI input 1HDMI output Minimum maximum level T M D S 2 9V 3 3V Input EDID Use the system default EDID supports EDID mapping to the input R...

Page 21: ...Noise 0 05 1 kHz with rated voltage Signal to Noise S N 80dB Stereo separation 80dB 1 kHz Signal type stereo Impedance input 10 k unbalanced maximum input level 19 5dBu Control types Front panel Illu...

Reviews: