background image

 

 

Maximum pixel clock 

225MHz 

Recommended  cable 
length 

The maximum transmission distance is ≤100m  
(we recommend shielded CAT6A cables, e.g. Belden 10GX) 

Supported resolution 

640x480@60Hz;800x600@60Hz;1024x768@60Hz;1280x720@60Hz;1280
x800@60Hz;1280x960@60Hz;1280x1024@60Hz;1360x768@60Hz;1366x
768@60Hz;1400x1050@60Hz;1440x900@60Hz;1600x1200@60Hz;1680x
1050@60Hz;1920x1080@50Hz;1920x1080@60Hz;1920x1200@60Hz 

Audio signal 

Input/output interface 

9x 3-pin Phoenix connectors with unbalanced audio input 
Stereo  audio  amplifier  output  on  one  4-pin  Phoenix  connector  (not  for 
Display Port audio) 

Gain 

0 dB 

Frequency response 

20 Hz~20 kHz 

THD + Noise 

0.05%@1 kHz (with rated voltage) 

Signal-to-Noise(S/N ) 

>80dB 

Stereo separation 

>80dB@1 kHz 

Signal type 

stereo 

Impedance 

input:>10 kΩ (unbalanced) 

maximum input level 

+19.5dBu 

Control types 

Front panel 

Illuminated buttons with LCD screen status display 

Serial control interface  RS-232, 9-pin female D-type interface  
Baud rate and protocol  Baud rate:115200,Data bits: 8 bits, stop bits:1, no parity 
Serial port pinout 

2=TX, 3=RX, 5=GND 

Ethernet interface 

RJ-45 female interface 

Ethernet protocol 

TCP/IP 

Ethernet control rate 

Adaptive 10M/100M, full-duplex or half-duplex 

HDBaseT remote 

HDBaseT remote control (RS232) 

Specification 

Power supply 

100VAC~240VAC, 50/60Hz 

Temperature 

Storage and operation temperature:-20°~+70°C 

Humidity 

Storage and operation humidity:0 ~.95% 

Chassis Size 

483(L) x 230 (W) x 44mm (H) 

Product weight 

2.3kg 

 

MTBF 

30,000 hours 

 

 

 

Summary of Contents for UP-1200

Page 1: ...Switching Scaler Version 1 1 Operating Instructions Thank you for purchasing our product Please be sure to read this instruction manual carefully before using our product UP 1200 Operating instructio...

Page 2: ...insulation occurring within the equipment may cause people suffer from shock CE certification means that the product has reached the directive safety requirements defined by the European Union Users...

Page 3: ...g Only after cutting down all external power source can install wiring operation begin or it may cause electric shock or equipment damage This product grounds by the grounding wires To avoid electric...

Page 4: ...ion 3 2 2 RJ45 network cable producing methods 4 2 3 Diagram of system connection 5 2 4 Panel operating instructions 5 2 4 1 LCD display 5 2 4 2 Button lights 5 2 4 3 Operation introduction 5 2 4 4 Op...

Page 5: ...ontrol Therefor the UP 1200 can be widely used in broadcast environments conference rooms education facilities command and control centers and other occasions 1 1 Features Supports 9 video signal inpu...

Page 6: ...if you switch between the inputs audio follows video But you can manually select a different audio source audio breakaway for a video source By pressing the AV button you can manually select an audio...

Page 7: ...VGA1 VGA2 video input interface and AUDIO INPUTS 1 4 audio interface have access to signals AUDIO INPUTS 1 and CV signal default fixed synthesis HDIM output AUDIO INPUTS 2 and YPbPr signal default fi...

Page 8: ...ked with different colors There are two methods of twisted pair connection EIA TIA 568B standard and EIA TIA 568A standard T568A line order 1 2 3 4 5 6 7 8 White and green green White and orange blue...

Page 9: ...l light up red You can setup the device by pressing the button MENU Menu operation steps can be summarized as Enter the menu choose option with parameter knob select option with ENTER button change pa...

Page 10: ...desired setting then press ENTER Step three Turn the PARAMETER knob to change the desired parameter then press ENTER to confirm the selection Step four Press the MENU to return to the previous menu If...

Page 11: ...just option 7 Press ENTER to enter the option parameter settings The LCD shows the current brightness value Use the PARAMETER knob to set the brightness value to 60 8 Press ENTER to confirm the change...

Page 12: ...COMM TEC Germany www comm tec de 8 COMM TEC UP 1200 Switching Scaler Manual...

Page 13: ...OMM TEC UP 1200 Switching Scaler Manual 2 5 Menu structure VGA Adjust is only valid when a VGA source has been connected to the UP 1200 COPY TO HDMI in EDID menu is only valid when a sink has been con...

Page 14: ...g Scaler Manual Chapter Three Control Codes RS232 communication RS232 communications settings Baud rate 115200 configurable Data bits 8 Parity None Stop bits 1 Flow control None TCP IP communication T...

Page 15: ...n S AUDIO 0 AUDIO 1 INPUT Select the AUDIO 1 INPUT S AUDIO 1 AUDIO 2 INPUT Select the AUDIO 2 INPUT S AUDIO 2 AUDIO 3 INPUT Select the AUDIO 3 INPUT S AUDIO 3 AUDIO 4 INPUT Select the AUDIO 4 INPUT S...

Page 16: ...Response Description S OUTPUT 0 OUTPUT 640x480 60Hz Set output resolution to 640x480 60Hz S OUTPUT 1 OUTPUT 800x600 60Hz Set output resolution to 800x600 60Hz S OUTPUT 2 OUTPUT 1024x768 60Hz Set outp...

Page 17: ...9 it means that the audio input are the embedded audio signals of the digital inputs HDMI1 HMDI2 HDMI3 and HDBaseT For example For adjust the second audio input to 12dB the corresponding command is A...

Page 18: ...ut H Start 1 Move the VGA input image one column right HTotal VGA Input H Total 1 Add 1 column to the total of VGA input images HTotal VGA Input H Total 1 Remove 1 column of the total of VGA input ima...

Page 19: ...AR 192 168 1 1 Set the gateway SUBR 255 255 255 0 SUBR 255 255 255 0 Set the subnet mask SPORT 6666 SPORT 6666 Set connection port number SIPR SIPR 192 168 1 190 Get the IP address GAR GAR 192 168 1 1...

Page 20: ...2 25 Gbps lane Interface HDMI A interface Type A connector 3 HDMI input 1HDMI output Minimum maximum level T M D S 2 9V 3 3V Input EDID Use the system default EDID supports EDID mapping to the input R...

Page 21: ...Noise 0 05 1 kHz with rated voltage Signal to Noise S N 80dB Stereo separation 80dB 1 kHz Signal type stereo Impedance input 10 k unbalanced maximum input level 19 5dBu Control types Front panel Illu...

Reviews: