4K 4x4 HDBaseT Matrix Switcher
Comm-Tec S.r.l.
24
www.comm-tec.it
Command
Function
Feedback
Example
EDIDPCM[x].
Set the audio part of input port [x] to PCM
format in EDID database.
EDIDPCM[x]
EDIDG[x].
Get EDID data from output [x] and
display the output port number.
Hexadecimal EDID
data and carriage
return character
EDIDMInit.
Restore the factory default EDID data of
every input.
EDIDMInit.
EDIDM[X]B[Y].
Manually EDID switching. Enable
input[Y] to learn the EDID data of
output[X]. If the EDID data is not
available, then set it as initialized EDID
data.
EDIDM[X]B[Y]
EDIDUpgrade[x].
Upgrade EDID data via the RS232 port.
[x] is the input port, when the value of X
is 9, it means to upgrade all input ports.
When
the
switcher
receives
the
command, it will show a message to
prompt you to send EDID file (.bin file).
Operations will be canceled after 10
seconds. Please cut off all connections of
HDBaseT ports.
Please send the
EDID file
EDID/[x]/[y].
Set the EDID data of input port [x] to built-
in EDID No.[y].
[y]=1~5, correspond to the 5 embedded
EDID data separately
EDID/[x]/[y]
UpgradeIntEDID[
x].
Upgrade one of the 5 embedded EDID
data, x is the serial number for EDID data:
1. 1080P 2D 2CH
2. 1080P 3D 2CH
3. 1080P 2D Multichannel
4. 1080P 3D Multichannel
5. 3840x2160 2D (30Hz)
When the switcher gets the command, it
will show a message to send EDID file
(.bin file). Operations will be invalid after
10 seconds.
Please send the
EDID file