Clima Flex Two-pipe One-way Cassette
29
11.2 Troubles and causes of remote controller
11.3 Malfunctions and malfunction code
If anything happens like the situation described below, please shut off the power supply of the unit and contact
with the customer service center immediately.
(
×
Extinguish,
☆
Flash at 5Hz)
Symptoms
Causes
The fan speed can not be
changed.
Check whether the MODE
indicated on the display is
"AUTO"
Check whether the MODE
indicated on the display is
"DRY"
When the automatic mode is
selected, the air conditioner will
automatically change the fan
speed.
When dry operation is selected,
the air conditioner automatically
change the fan speed. The fan
speed can be selected during
"COOL" , "FAN ONLY",
and "HEAT"
The remote controller signal is
not transmitted even when
the ON/OFF button is pushed.
Check whether the batteries
in the remote controller are
exhausted.
The power supply is off.
No receiving tone sounds
from the indoor unit even
when the ON/OFF button is
pressed.
Check whether the signal
transmitter of the remote
controller is properly directed
to the infrared signal receiver
of the indoor unit when the
ON/OFF button is pressed.
Directly transmit the signal transmitter of
the remote controller to the
infrared signal receiver of the
indoor unit, and then repeatly
push the ON/OFF button twice.
The indication on the display
disappears after a lapse of
time.
Check whether the timer
operation has come to an
end when the TIMER OFF
is indicated on the display.
The air conditioner operation will
stop up to the set time
The TIMER ON indicator
goes off after a lapse of
certain time.
Check whether the timer
operation is started when
the
TIMER ON
is indicated
on the display.
Up to the set time, the
air conditioner will automatically
start and the appropriate
indicator will go off.
The TEMP. indicator does
not come on.
Check whether the MODE
indicated on the display is
FAN ONLY
The temperature cannot be set during
FAN mode.
Solution
×
NO.
Malfunction
running lamp
timer lamp
defrosting lamp
alarm lamp
alarm lamp
1
2
3
4
Room temperature sensor
checking channel is abnormal
Evaporator sensor checking
channel is abnormal
EEPROM malfunction
Water-level switch
malfunction
×
×
×
×
×
×
×
×
×
×
☆
☆
☆
E2
E3/E4
E7
E8
☆
☆