![COMFORT-AIRE A-SVH09SA-0 Service Manual Download Page 34](http://html.mh-extra.com/html/comfort-aire/a-svh09sa-0/a-svh09sa-0_service-manual_2641633034.webp)
Service Manual -
SVH 09/12/18/24 Series
34
30
9.3.2
Indoor / outdoor unit’s communication
diagnosis and solution
(E1)
Error Code
E1
Malfunction conditions Indoor unit does not receive the feedback from outdoor unit during
110 seconds and this condition happens four times continuously.
Possible
causes
●
Wiring
error
●
Indoor or outdoor PCB faulty
Troubleshooting:
No
Yes
Yes
No
No
Yes
No
Yes
No
Power off, then restart the unit 2 minutes later.
Is the error extinguished?
Measure Vs.
Is the voltage moving alternately
between -25V to 25V?
Check the outdoor wiring connection.
Is the wiring correct?
Replace the reactor
Does reactor
check normal?
Check the
in
door wiring connection.
Is the wiring correct?
Replace the indoor main PCB.
Power on.
Is the error extinguished?
Replace the outdoor main PCB.
Replace the outdoor main PCB.
Power on.
Is the error extinguished?
Replace the indoor PCB.