LCD Panel 

Function 

Information about the time of autonomy

 

 

 

Displays the estimated autonomy of the UPS 
H: hours, M: minutes, S: seconds 

Configuration and error information

 

 

Displays the parameter value. 

 

 

Displays an error or warning code. 

Output information  

 

Displays the voltage or frequency parameters and the battery voltage. 
Vac: output voltage, Hz: output frequency, Vdc: battery voltage 

Load information 

 

Indicates load level 0-24%, 25-49%, 50-74% and 75-100%. 

 

Indicates an overload condition. 

 

Indicates a short circuit condition at the device output. 

Information on programmable outputs 

 

Indicates whether a programmable socket group is configured. 

Information about the operating mode 

 

Indicates that the UPS is connected to the 230V mains. 

 

Indicates the UPS is running on battery. 

 

Indicates the UPS is operating in Bypass mode. 

 

Indicates that the ECO mode is on. 

 

Indicates that the UPS inverter is running. 

 

Indicates that the output voltage is present. 

 

Indicates the sound on the UPS is muted. 

Battery information 

 

Indicates 0-24%, 25-49%, 50-74%, and 75-100% charge level. 

 

Indicates a defective battery condition. 

 

Indicates a low battery condition. 

Information about power supply parameters and battery voltage 

 

Displays input voltage, frequency, and battery voltage. 
Vac: 230V mains voltage, Vdc: battery voltage, Hz: mains frequency 

 

 

Summary of Contents for COVER Basic 1K

Page 1: ...h against fire To the connector marked EPO connect the emergency switch against fire The standard configuration of the EPO is an NC normally closed type connector i e for the correct operation of the...

Page 2: ...UPS to activate the test OFF ENTER UPS shutdown Press and hold for 2 seconds to turn off the UPS or switch to Bypass mode depending on the selected operation configuration options Confirm Selection P...

Page 3: ...on programmable outputs Indicates whether a programmable socket group is configured Information about the operating mode Indicates that the UPS is connected to the 230V mains Indicates the UPS is runn...

Page 4: ...erter available not available ENA Converter function available DIS Converter function unavailable default 03 Frequency setting Frequency setting for battery operation BAT 50 50Hz output frequency BAT...

Page 5: ...olds results in the inaccessibility of the bypass path HLS Bypass high voltage threshold Using the arrow keys it is possible to select the voltage of 230V 264V default 264V LLS Bypass low threshold Us...

Page 6: ...the range of 40 70Hz it is possible to set a fixed value of the output voltage frequency of 50 or 60Hz This mode also charges the batteries Battery operation mode In the event of a power failure or w...

Page 7: ...s Battery failure Beep every 2 seconds UPS off Bypass out of tolerance Beep every 2 seconds Bypass frequency unstable Beep every 2 seconds Error EEPROM Beep every 2 seconds Fan error Beep every 2 seco...

Page 8: ...tion follow the instructions on the computer screen You must restart your computer after the installation process is complete Restarting the computer will automatically launch ViewPower as shown by th...

Reviews: