LCD display operation  

Function keys 

 

 

 

Button 

Function 

ON/MUTE 

 

Turn on the UPS: Press and hold for 2 seconds to turn on the UPS. 

 

Alarm mute: When the UPS is on battery, press and hold for 3 seconds to silence or enable 
the buzzer. Alarm silencing is not possible in the event of an alarm condition. 

 

Up Arrow: Key to scroll up to the previous line in the UPS setup menu. 

 

Turning on the self test mode: Press and hold for 3 seconds in time normal operation of the 
UPS to activate the test. 

OFF/ENTER 

 

UPS shutdown: Press and hold for 2 seconds to turn off the UPS or switch to Bypass mode 
(depending on the selected operation configuration options). 

 

Confirm Selection: Press the key to confirm the selection in the UPS setup menu. 

SELECT 

 

Switching between display information: Press to switch between information displayed on 
the panel such as voltage, frequency, battery voltage. 

 

Setup menu: Press and hold for 5 seconds to enter the UPS setup (configuration) menu. This 
function is available only when the UPS is in Bypass or Stand-By mode. 

 

Down arrow key: A key for scrolling down to the next line in the UPS setup menu. 

 
LCD Panel 

 

Summary of Contents for COVER Basic 1K

Page 1: ...h against fire To the connector marked EPO connect the emergency switch against fire The standard configuration of the EPO is an NC normally closed type connector i e for the correct operation of the...

Page 2: ...UPS to activate the test OFF ENTER UPS shutdown Press and hold for 2 seconds to turn off the UPS or switch to Bypass mode depending on the selected operation configuration options Confirm Selection P...

Page 3: ...on programmable outputs Indicates whether a programmable socket group is configured Information about the operating mode Indicates that the UPS is connected to the 230V mains Indicates the UPS is runn...

Page 4: ...erter available not available ENA Converter function available DIS Converter function unavailable default 03 Frequency setting Frequency setting for battery operation BAT 50 50Hz output frequency BAT...

Page 5: ...olds results in the inaccessibility of the bypass path HLS Bypass high voltage threshold Using the arrow keys it is possible to select the voltage of 230V 264V default 264V LLS Bypass low threshold Us...

Page 6: ...the range of 40 70Hz it is possible to set a fixed value of the output voltage frequency of 50 or 60Hz This mode also charges the batteries Battery operation mode In the event of a power failure or w...

Page 7: ...s Battery failure Beep every 2 seconds UPS off Bypass out of tolerance Beep every 2 seconds Bypass frequency unstable Beep every 2 seconds Error EEPROM Beep every 2 seconds Fan error Beep every 2 seco...

Page 8: ...tion follow the instructions on the computer screen You must restart your computer after the installation process is complete Restarting the computer will automatically launch ViewPower as shown by th...