![Comelit VIP System Installer Manual Download Page 56](http://html.mh-extra.com/html/comelit/vip-system/vip-system_installer-manual_2640256056.webp)
56
•
Confi guring the Actuator Directory
1.
Access the installer menu.
2.
Select the
Special Settings
menu by pressing
,
and press
to access it.
INSTALLER MENU
Special Settings
3.
Select the Actuator menu by pressing
,
and press
to access
it.
SPECIAL SETTINGS MENU
Door open
Actuator
Self-ignition
Call
Alarms
Set ringtone repetition
4.
Press the
button.
5.
Press button
to access the
Con
fi gure name
menu.
ACTUATOR DIRECTORY
Not assigned
Not assigned
Not assigned
Not assigned
Not assigned
Not assigned
Edit
6. Enter the desired name using buttons
,
to change the letters,
,
to move right or left and
to delete.
CONFIGURE DIRECTORY
Configure ViP address
Configure name
EDIT ENTRY
Configure Name
Left
Right
Edit
S o u t h g a t e
7. Enter the desired name using buttons
,
to change the letters,
,
to move right or left and
to delete.
EDIT ENTRY
Configure Name
S M I T H
Left
Right
Edit
CONFIGURE DIRECTORY
Configure ViP address
Configure name
CONFIGURE VIP ADDRESS
0 0 0 0 0 1 0 1
ViP address:
Left
Right
Camera number
Automatic camera
1
8. Press button
to return to the previous menu.
9. Select the
Confi gure VIP ad
dress
menu by pressing
,
and
press
to access it.
10. Select the fi elds which can be changed using
, and change the
value using
,
or
.
• The
VIP address
functions determines the address of external unit
Art. 4662C or remote camera module Art. 1445.
•
Select the
Automatic camera
function to link the camera for external
unit Art. 4662C.
•
Sele
ct the
Camera number
function and enter the input number
from the 4 available when using a remote camera module Art. 1445.
11.
Press
to exit and save the changes.