19
SH
V4
SH
V3
SH
V2
SH
V1
GND
AUX
12 - 24 V DC power supply terminal
Earth terminal
1
2
3
5
4
1
2
3
5
4
1.
Video signal from cameras input terminals
2.
Secondary power supply terminals.
To be used if the POE network power su
pply is insufficient
Input terminal for composite video signal from camera 1
Input terminal for composite video signal from camera 2
Input terminal for composite video signal from camera 3
Input terminal for composite video signal from camera 4
Camera 1 shield terminal
Camera 2 shield terminal
Camera 3 shield terminal
Camera 4 shield terminal
VIP system accessories
Remote camera module Art. 1445
Remote camera module Art. 1445 transmits the video signals received from 4 cameras.
D+
D-
GND
Technical characteristics
Absorption
Min. 0.7 W Max. 2.6 W
Power supply
36/57 Vdc 3A Max.
Temperature thresholds
-30 / +55°C
Dimensions
4 DIN modules / H: 3.6 cm W: 6.5 cm D: 8.3 cm
N.B. Up to this point, the functions linked to the RS485 line have not been implemented.
4.
RS485 line terminals.
3.
Network connection Ethernet port.
5.
RS485 line closure jumper
Earth terminal
RS485 data line
For wiring details, refer to the diagrams section at the end of this manual.