background image

2

Description ....................................................................................... 3

Touch-sensitive button activation ..........................................................4
Buttons ......................................................................................................4
Indicator LED ............................................................................................4
Press and hold keys 

(Disabled by default from firmware version 1.5.0) ..4

Automatic door opening on receipt of call (Doctor mode)...................4
Automatic answer (Hands-Free function) ..............................................4

Technical specifications ................................................................. 5

Installation ........................................................................................ 6

Installed in flush-mounted box art. 6117 ................................................6
Art. 6620 Surface mounting / in 503 series box / round box ................7

Connections ..................................................................................... 8

Variant: connection of call repetition device art. 1122/A ......................8

Settings ............................................................................................ 9

Main and secondary door entry monitors .............................................9
Power supply management .....................................................................9

Configuring buttons ...................................................................... 10

Basic configuration ................................................................................10
Legend.....................................................................................................10

Advanced configuration ........................................................................11

Intercom call .....................................................................................11

Introduction ...............................................................................11

General

 intercom call: button programming .............................11

Intercom call to selective address: button programming ..........12
Selective intercom address .......................................................12
Assigning selective address ......................................................12
Deleting the selective address of the door entry monitor..........12

Generic actuator, coded actuator .....................................................13

Generic 

actuator

: button programming ....................................13

Coded 

actuator

: button programming......................................13

Other functions: button programming ..............................................14
Programming range ..........................................................................14
LED/alarm/lock-release/actuator programming ...............................15
Changing the ringtone ......................................................................15
Programming reset ...........................................................................16

System performance and layouts ................................................ 16

Addressing table ............................................................................ 17

Table of contents

Warning

Intended use

 

This Comelit product has been designed and manufactured for use in the creation of audio and video communication systems in residential, 

commercial, industrial and public buildings.

Installation

 

All activities connected to the installation of Comelit products must be carried out by qualified technical personnel, with careful observation of the 

indications provided in the Manuals / Instruction sheets supplied with those products.

Wires

 

Disconnect the power supply before carrying out any operations on the wiring. 

 

Use wires with a cross-section suited to the distances involved, observing the instructions provided in the system manual.

 

We advise against running the system wires through the same duct as power cables (230V or higher).

Safe usage

 

To ensure Comelit products are used safely:

 

•  carefully observe the indications provided in the Manuals / Instruction sheets,

 

•  make sure the system created using Comelit products has not been tampered with / damaged. 

Maintenance

 

Comelit products do not require maintenance aside from routine cleaning, which should be carried out in accordance with the indications provided 

in the Manuals / Instruction sheets.

 

Any repairs must be carried out:

  

•  for the products themselves, exclusively by 

Comelit Group S.p.A.

,

 

•  for the systems, by qualified technical personnel.

Disclaimer

 

Comelit Group S.p.A. 

does not assume any responsibility for

 

•  any purpose other than the intended use,

 

•  failure to observe the indications and warnings contained in this Manual / Instruction sheet.

 

Comelit Group S.p.A. 

reserves the right to change the information provided in this Manual / Instruction Sheet at any time and without prior notice.

Summary of Contents for Icona Manager

Page 1: ...Icona 2 wire door entry monitor Art 6601W Art 6601W BM Passion Technology Design EN TECHNICAL MANUAL...

Page 2: ...communication systems in residential commercial industrial and public buildings Installation All activities connected to the installation of Comelit products must be carried out by qualified technica...

Page 3: ...5 6 access to programming DIP 7 for power supply voltage management Paragraph Power supply management on page 9 DIP 8 for setting main and secondary door entry monitor Paragraph Main and secondary do...

Page 4: ...he function associated with it 1 2 Press and hold keys Disabled by default from firmware version 1 5 0 Pressing and holding keys adds further functions to the door entry monitor Carry out the procedur...

Page 5: ...s Loudspeaker 40 x 20 H mm 8 Ohm 2W 40 x 20 H mm 8 Ohm 2W Technologies implemented Full Duplex Full Duplex ELECTRICAL SPECIFICATIONS Type of power supply Power supply via video entry bus Power supply...

Page 6: ...6 Installation Installed in flush mounted box art 6117 3 160 cm 130 cm 2 14 2 cm 14 7 cm 1 2 1 6 Lmax 10 cm Lmin 6 cm 5 2 3 4 5 1 4 1 1 2 CLACK 2 9 2 1 8 2 1 7 1 2 DISASSEMBLY...

Page 7: ...ting in 503 series box round box 2 1 7 2 1 6 1 2 3C 2 1 3B Lmax 7 cm Lmin 6 5 cm 4A with Art 6620 2 1 5A with Art 6620 1 2 1 2 CLACK 8 1 2 DISASSEMBLY Art 6620 optional 160 cm 130 cm 2 2 1 3A with Art...

Page 8: ...A 12V IN 2 1 IN 2 1 P F C L L P F C S S C N O N C 20 m MAX Connect a single call repetition device for each user code If inductive loads are connected the connection of 470nF capacitance in parallel w...

Page 9: ...t DIP 8 of S2 to ON S2 1 2 3 4 6 7 5 8 S2 1 2 3 4 6 7 5 8 Power supply management For correct power supply management set S2 DIP 7 in accordance with the type of system and its configuration in system...

Page 10: ...phone call PAN Priority call to switchboard not available in KIT systems NULL No function PROG With these S2 DIP switch settings the buttons control the programmed functions as in the Advanced config...

Page 11: ...iguration table 4 Set the S1 DIP switches according to the call address of the desired apartment See Addressing table on page 17 5 Press and release the button to be associated with the function Corre...

Page 12: ...g the next key by repeating the process from step 5 onwards 7 Exit programming mode by setting S2 DIP switch 6 to OFF LED switches off S2 8 Set S2 DIP switches 1 2 3 4 to ON 9 Return S1 DIP switches t...

Page 13: ...g S2 DIP switch 6 to OFF LED switches off S2 7 Set S2 DIP switches 1 2 3 4 to ON 8 Return S1 DIP switches to the original combination 1 Take note of the S1 DIP switch settings 2 To enter programming m...

Page 14: ...tch combination in which the desired functions corresponding to the buttons you want to program appear then set the S2 DIP switches Example For button 4 Self Activation AI and button 5 Call to Seconda...

Page 15: ...is busy 2 Press and release Once 1 confirmation tone is emitted to change the ringtone for calls from the external entrance panel twice 2 confirmation tones are emitted to change the ringtone for call...

Page 16: ...on the system type that best meets your requirements Simplebus2 audio video kit with power supply unit art 1209 for the creation of audio video systems for individual residences Simplebus2 audio vide...

Page 17: ...8 14 2 3 4 44 3 4 6 74 2 4 7 104 4 6 7 134 2 3 8 164 3 6 8 194 2 7 8 224 6 7 8 15 1 2 3 4 45 1 3 4 6 75 1 2 4 7 105 1 4 6 7 135 1 2 3 8 165 1 3 6 8 195 1 2 7 8 225 1 6 7 8 16 5 46 2 3 4 6 76 3 4 7 10...