Take note of the S2, S1 settings and restore on completion of programming
LED/alarm/lock-release/actuator programming
1.
2.
3.
4.
Input IN 1- IN 2
LED (default)*
S2
x4
OK prog:
x10
KO prog:
S2
Input CFP2 - IN 1
ALARM*
Input CFP2 - IN 1
LOCK-RELEASE*
S2
Input CFP2 - IN 1
CODED
ACTUATOR*
S1
set code,
Input CFP2 - IN 1
GENERIC ACTUATOR*
S1
* See
Changing the ringtone
1.
Press and hold
for 6 sec.
»
a confirmation tone is emitted
»
the LED
flashes
√
the procedure can only take place while the system is in standby; otherwise the LED
will flash 4 times to inform the
user that the system is busy
2.
Press and release
Once
(1 confirmation tone is emitted) to change the ringtone for calls from the external entrance panel.
twice
(2 confirmation tones are emitted) to change the ringtone for calls from the switchboard.
3 times
(3 confirmation tones are emitted) to change the ringtone for intercom calls made from the door entry monitor.
4 times
(4 confirmation tones are emitted) to change the floor door call ringtone.
Any further pressing of the button repeats the sequence described above.
3.
Press and release to scroll through the available ringtones in sequence.
4.
Press the buttonto confirm selection of the last ringtone heard and to exit change door entry monitor ringtone mode.
»
a confirmation tone is emitted
»
LED
switches off
When the procedure is complete, restore the initial DIP-switch combination.