background image

3

Description

1. 

Microphone

2. 

4.3’’ LCD screen

3. 

Buttons / Indicator LEDs

4. 

Loudspeaker

5.  S1 DIP-switches:

 Microswitches for assigning user code according t

“Addressing table" on page 17

6.  CV1 CV2

 Jumper to be removed in case of separate power supply

7.  CV5

 Jumper for video closure. In systems with more than one door entry monitor connected in cascade, only the door 

entry monitor furthest away must have CV5 closed

8.  CV6 position A 

= contact IN1-IN2 > LED (Default)

CV6 position B

 = contact CFP2-IN1 > ALARM / LOCK-RELEASE / ACTUATOR

9.  S2 DIP-switches:

 Microswitches for button and function programming

DIP 1-2-3-4 for button function programming
DIP 5-6 access to programming
DIP 7 for power supply voltage management. Paragraph 

“Power supply management" on page 9

DIP 8 for setting main and secondary door entry monitor. Paragraph 

“Main and secondary door entry monitors" on page 9

10. M2 Terminal block for system connection:

CFP1 CFP2

 Floor door call input

S+ S-

 Terminals for call repetition device

IN1 IN2

 LED input (programmable)

11. M1 Terminal block for system connection:

L L

 Bus line connection terminals

- +

 Power supply terminals

1

2

4

3

11.

6.
7.

8.

5.

9.

10.

B

A

The door entry monitor can be used in Simplebus2 audio/video systems.

Icona 6601W is a colour monitor equipped as standard with 9 function buttons and 6 adjustment buttons.
Icona 6601W/BM is a colour monitor with 9 function buttons and 6 adjustment buttons, equipped with a magnetic amplification 
system for hearing aid devices.

Summary of Contents for Icona Manager

Page 1: ...Icona 2 wire door entry monitor Art 6601W Art 6601W BM Passion Technology Design EN TECHNICAL MANUAL...

Page 2: ...communication systems in residential commercial industrial and public buildings Installation All activities connected to the installation of Comelit products must be carried out by qualified technica...

Page 3: ...5 6 access to programming DIP 7 for power supply voltage management Paragraph Power supply management on page 9 DIP 8 for setting main and secondary door entry monitor Paragraph Main and secondary do...

Page 4: ...he function associated with it 1 2 Press and hold keys Disabled by default from firmware version 1 5 0 Pressing and holding keys adds further functions to the door entry monitor Carry out the procedur...

Page 5: ...s Loudspeaker 40 x 20 H mm 8 Ohm 2W 40 x 20 H mm 8 Ohm 2W Technologies implemented Full Duplex Full Duplex ELECTRICAL SPECIFICATIONS Type of power supply Power supply via video entry bus Power supply...

Page 6: ...6 Installation Installed in flush mounted box art 6117 3 160 cm 130 cm 2 14 2 cm 14 7 cm 1 2 1 6 Lmax 10 cm Lmin 6 cm 5 2 3 4 5 1 4 1 1 2 CLACK 2 9 2 1 8 2 1 7 1 2 DISASSEMBLY...

Page 7: ...ting in 503 series box round box 2 1 7 2 1 6 1 2 3C 2 1 3B Lmax 7 cm Lmin 6 5 cm 4A with Art 6620 2 1 5A with Art 6620 1 2 1 2 CLACK 8 1 2 DISASSEMBLY Art 6620 optional 160 cm 130 cm 2 2 1 3A with Art...

Page 8: ...A 12V IN 2 1 IN 2 1 P F C L L P F C S S C N O N C 20 m MAX Connect a single call repetition device for each user code If inductive loads are connected the connection of 470nF capacitance in parallel w...

Page 9: ...t DIP 8 of S2 to ON S2 1 2 3 4 6 7 5 8 S2 1 2 3 4 6 7 5 8 Power supply management For correct power supply management set S2 DIP 7 in accordance with the type of system and its configuration in system...

Page 10: ...phone call PAN Priority call to switchboard not available in KIT systems NULL No function PROG With these S2 DIP switch settings the buttons control the programmed functions as in the Advanced config...

Page 11: ...iguration table 4 Set the S1 DIP switches according to the call address of the desired apartment See Addressing table on page 17 5 Press and release the button to be associated with the function Corre...

Page 12: ...g the next key by repeating the process from step 5 onwards 7 Exit programming mode by setting S2 DIP switch 6 to OFF LED switches off S2 8 Set S2 DIP switches 1 2 3 4 to ON 9 Return S1 DIP switches t...

Page 13: ...g S2 DIP switch 6 to OFF LED switches off S2 7 Set S2 DIP switches 1 2 3 4 to ON 8 Return S1 DIP switches to the original combination 1 Take note of the S1 DIP switch settings 2 To enter programming m...

Page 14: ...tch combination in which the desired functions corresponding to the buttons you want to program appear then set the S2 DIP switches Example For button 4 Self Activation AI and button 5 Call to Seconda...

Page 15: ...is busy 2 Press and release Once 1 confirmation tone is emitted to change the ringtone for calls from the external entrance panel twice 2 confirmation tones are emitted to change the ringtone for call...

Page 16: ...on the system type that best meets your requirements Simplebus2 audio video kit with power supply unit art 1209 for the creation of audio video systems for individual residences Simplebus2 audio vide...

Page 17: ...8 14 2 3 4 44 3 4 6 74 2 4 7 104 4 6 7 134 2 3 8 164 3 6 8 194 2 7 8 224 6 7 8 15 1 2 3 4 45 1 3 4 6 75 1 2 4 7 105 1 4 6 7 135 1 2 3 8 165 1 3 6 8 195 1 2 7 8 225 1 6 7 8 16 5 46 2 3 4 6 76 3 4 7 10...

Reviews: