background image

5

Technical specifications

GENERAL DATA

6601W

6601W/BM

Product height (mm)

147

147

Product width (mm)

143

143

Product depth (mm)

23

23

Product weight (g)

500

500

Product colour

White RAL9003, base grey RAL7001

White RAL9003, base grey RAL7001

Material

ABS, Glass

ABS, Glass

Flush mounting

Yes, with specific accessory

Yes, with specific accessory

Surface mounting

Yes, with specific accessory

Yes, with specific accessory

Desk base mounting

Yes, with specific accessory

Yes, with specific accessory

COMPATIBLE SYSTEMS

Simplebus 2 audio/video with

power supply unit art. 4888C

Yes

Yes

Simplebus 2 audio/video with

power supply unit art. 1210/1210A

Yes

Yes

Simplebus 2 audio/video kit with

power supply unit art. 1209

Yes

Yes

DISPLAY SPECIFICATIONS

Size (inches) (")

4.3

4.3

Aspect ratio

16:9

16:9

Resolution (pixels) 

480x272

480x272

AUDIO SPECIFICATIONS

Type

Hands-free

Hands-free

Microphone

6 mm (Ø), Omnidirectional

6 mm (Ø), Omnidirectional

Magnetic induction system

No

Yes

Loudspeaker

40 (ø) x 20 (H) mm, 8 Ohm, 2W

40 (ø) x 20 (H) mm, 8 Ohm, 2W

Technologies implemented

Full-Duplex

Full-Duplex

ELECTRICAL SPECIFICATIONS

Type of power supply

Power supply via video entry bus

Power supply via video entry bus

Power supply voltage

22 to 34 VDC (Bus)

22 to 34 VDC (Bus)

Maximum absorption (W)

10.8

10.8

HARDWARE CHARACTERISTICS

Type of buttons

Capacitive

Capacitive

Service buttons

Lock-release, Answer, Silent, Door open

Lock-release, Answer, Silent, Door open

No. of programmable buttons for

additional functions

5

5

Terminals

L L - + CFP1 CFP2 S+ S- In1 In2

L L - + CFP1 CFP2 S+ S- In1 In2

Removable terminals

Yes

Yes

Number of inputs (no.)

2

2

SETTINGS

Loudspeaker volume

Yes

Yes

Ringtone volume

Yes

Yes

Screen brightness

Yes

Yes

Screen contrast

Yes

Yes

ENVIRONMENTAL AND CONFORMITY SPECIFICATIONS

IP protection rating

IP30

IP30

Operating temperature (°C)

5 to 40

5 to 40

Operating humidity (max RH - %) 

25 to 75

25 to 75

Environmental class

 I

 I

Conformity and Certifications

RoHS II - 2011/65/EU (EN 50581:2012), EMC 
2014/30/EU (EN 61000-6-1:2007, EN 61000-6-
3:2007+A1:2011)

RoHS II - 2011/65/EU (EN 50581:2012), EMC 
2014/30/EU (EN 61000-6-1:2007, EN 61000-6-
3:2007+A1:2011)

Summary of Contents for Icona Manager

Page 1: ...Icona 2 wire door entry monitor Art 6601W Art 6601W BM Passion Technology Design EN TECHNICAL MANUAL...

Page 2: ...communication systems in residential commercial industrial and public buildings Installation All activities connected to the installation of Comelit products must be carried out by qualified technica...

Page 3: ...5 6 access to programming DIP 7 for power supply voltage management Paragraph Power supply management on page 9 DIP 8 for setting main and secondary door entry monitor Paragraph Main and secondary do...

Page 4: ...he function associated with it 1 2 Press and hold keys Disabled by default from firmware version 1 5 0 Pressing and holding keys adds further functions to the door entry monitor Carry out the procedur...

Page 5: ...s Loudspeaker 40 x 20 H mm 8 Ohm 2W 40 x 20 H mm 8 Ohm 2W Technologies implemented Full Duplex Full Duplex ELECTRICAL SPECIFICATIONS Type of power supply Power supply via video entry bus Power supply...

Page 6: ...6 Installation Installed in flush mounted box art 6117 3 160 cm 130 cm 2 14 2 cm 14 7 cm 1 2 1 6 Lmax 10 cm Lmin 6 cm 5 2 3 4 5 1 4 1 1 2 CLACK 2 9 2 1 8 2 1 7 1 2 DISASSEMBLY...

Page 7: ...ting in 503 series box round box 2 1 7 2 1 6 1 2 3C 2 1 3B Lmax 7 cm Lmin 6 5 cm 4A with Art 6620 2 1 5A with Art 6620 1 2 1 2 CLACK 8 1 2 DISASSEMBLY Art 6620 optional 160 cm 130 cm 2 2 1 3A with Art...

Page 8: ...A 12V IN 2 1 IN 2 1 P F C L L P F C S S C N O N C 20 m MAX Connect a single call repetition device for each user code If inductive loads are connected the connection of 470nF capacitance in parallel w...

Page 9: ...t DIP 8 of S2 to ON S2 1 2 3 4 6 7 5 8 S2 1 2 3 4 6 7 5 8 Power supply management For correct power supply management set S2 DIP 7 in accordance with the type of system and its configuration in system...

Page 10: ...phone call PAN Priority call to switchboard not available in KIT systems NULL No function PROG With these S2 DIP switch settings the buttons control the programmed functions as in the Advanced config...

Page 11: ...iguration table 4 Set the S1 DIP switches according to the call address of the desired apartment See Addressing table on page 17 5 Press and release the button to be associated with the function Corre...

Page 12: ...g the next key by repeating the process from step 5 onwards 7 Exit programming mode by setting S2 DIP switch 6 to OFF LED switches off S2 8 Set S2 DIP switches 1 2 3 4 to ON 9 Return S1 DIP switches t...

Page 13: ...g S2 DIP switch 6 to OFF LED switches off S2 7 Set S2 DIP switches 1 2 3 4 to ON 8 Return S1 DIP switches to the original combination 1 Take note of the S1 DIP switch settings 2 To enter programming m...

Page 14: ...tch combination in which the desired functions corresponding to the buttons you want to program appear then set the S2 DIP switches Example For button 4 Self Activation AI and button 5 Call to Seconda...

Page 15: ...is busy 2 Press and release Once 1 confirmation tone is emitted to change the ringtone for calls from the external entrance panel twice 2 confirmation tones are emitted to change the ringtone for call...

Page 16: ...on the system type that best meets your requirements Simplebus2 audio video kit with power supply unit art 1209 for the creation of audio video systems for individual residences Simplebus2 audio vide...

Page 17: ...8 14 2 3 4 44 3 4 6 74 2 4 7 104 4 6 7 134 2 3 8 164 3 6 8 194 2 7 8 224 6 7 8 15 1 2 3 4 45 1 3 4 6 75 1 2 4 7 105 1 4 6 7 135 1 2 3 8 165 1 3 6 8 195 1 2 7 8 225 1 6 7 8 16 5 46 2 3 4 6 76 3 4 7 10...

Reviews: