background image

E

N

G

L

IS

H

FT CT 05

FT CT 05

5

4. IF IT IS NOT WORKING:

NO PHONE CONNECTION:
-  Check if the programming switch is set to 1. 
-  Check the connection by connecting the telephone direct to the main line.
-  Check the power on the Trunk terminals (A, B; TRUNK, TRUNK). This must be the same as on the telephone line terminals (TEL).

NO CONTACT WITH THE SIMPLEBUS SYSTEM:
-  Direct after programming the Simplebus code, the LED shows the status of the bus line. If the LED blinks 4 times, measure than the power between the bus line terminals 

(L - L). (This must be between 17 and 30VDC).

-  Did you program the right code? If any doubt, please follow the programming procedure mentioned in chapter 2.
-  If the telephone rings, but you are not able to speak, it could be that the interface, the reason could be the programmed bus mode in the interface. This could happen if you 

forgot to program the interface, while in the programming procedure the bus type automatically will be adapted. Please follow the programming procedure of chapter 2.

NO DIVERSION:
-  Be sure that the number of the diversion has been programmed properly. If the interface is connected to a telephone switchboard (PABX), normally there must be programmed 

a "0". For some switchboards it could be necessary to program a pause after the first number, by adding ## (wait after each # for an acknowledge).

5. SETTINGS OF THE INTERFACE: In the table below you find the default settings of the telephone interface. 

Settable functions  

 

 

Code

Default

Range

Example

A

Communication time (call + conversation) with “follow-me” 
function

*0nnn

090

000 en 180 *0030 (time to 30 sec.)

B

Call  time  from  external  unit  to  door-entry  phone  or  local 
telephone

*1nnn

030

000 en 180 *1040 (time to 40 sec.)

C

Conversation time after a local call from external unit

*2nnn

090

000 en 180 *2080 (time to 80 sec.)

D

Delay before “follow-me” (call to remote telephone)

*3nnn

005

000 en180

*3010 (time to 10 sec.)

E

Change Simplebus address manually* 

*9nnn

001

000 en 240 *9130 (address 130)

F

Set to Simpebus(1) manually (no mixer Art. 4888/4888C)

##10

##10

-

##10 (setting to  SB1)

G

Set  to  Simplebus(2)  or  SBC  manually  (mixer  Art. 
4888/4888C)

##11

##10

-

##11 (setting to SB2 or SBC)

H

Relay time on the interface

#9n

4

0 en 9

#98 (time to 8 sec.)

I

The interface does not send ack after a call

*#20

*#21

-

*#20 (to be used when Art. 2904 is positioned 
before  a  switching  device  Art.  1224A  or  Art. 
1424, i.e. on the incoming bus line connected 
to  the  LP-LP  terminals  of  the  switching 
device).

L

Relay on interface switched separately

##71

##70

-

##71  (the  relay  is  only  controlled  by  the 
command #*)

M

Keep local phone ringing, while "special follow me with call 
waiting"started (see point C)

##61

##60

-

##61 (the door-entry phone or local telephone 
continues to ring. Press 1 to answer from the 
remote telephone).

N

Reset to factory settings

*#0

-

-

*#0 (to factory settings)

* If you use this function, you also must setup the Simplebus mode (dafault SB1). If address 000 is programmed, the interface will activate on all codes.

If the system is working fine, but it is desired to change the factory settings, please follow the instructions below:
Important: An analogue telephone must be connected to the output of the telephone interface. 

1 Set the programming dipswitch to the position "ON". 
2 Choose between on of the codes mentioned in the table followed by the required setting.
Example: setting internal call time to 40 sec. (line 2) choose:

 After programming a confirmation beep will sound.

3 Set the programming dipswitch to the position "1" to enter into the normal mode.

6. SPECIFICATIES: 

System:  

  

Simplebus1, Simplebus2 and SBC audio and video (automatic detection).

Telephone:  

  

Analogue system, transparent for call identification

Connections:  

 12V~ 

Power connection 12VAC or 13,8VDC

 

 

 A, B 

Telephone line PSTN. Connection to the telephone provider or towards PABX

 

 

 

(TRUNK, TRUNK)

 

 

 Tel 

Connections for an analogue telephone

 

 

 NC 

Connection normally closed contact of relay in Art. 2904 

 

 

 C 

Connection common contact of relay in Art. 2904 

 

 

 NO 

Connection normally open contact of relay in Art. 2904 

 

 

 L,L 

Connections for Simplebus (1, 2 or SBC) bus line

 

 

 GND 

For later expansion purpose

 

 

 Do 

For later expansion purpose

 

 

 V+ 

For later expansion purpose

Settings:  

1. Mic. Potentiometer for microphone setting (outside to inside)

 

 

2. LS.  Potentiometer for loudspeaker setting (inside to outside)

Summary of Contents for FT CT 05

Page 1: ...rigoni 5 24020 Rovetta S Lorenzo BG Italy tel 39 0346 750 011 fax 39 0346 71436 www comelit eu www simplehome eu info comelit it commerciale italia comelit it export department comelit it Interfaccia...

Page 2: ...e nella modalit Seguimi mentre suoner anche il telefono e sar possibile rispondere tramite un citofono un monitor o un telefono Quando si risponde dal telefono che stato raggiunto dal Seguimi si senti...

Page 3: ...88C 10 10 10 settaggio in SB1 G Settaggio manuale in Simplebus 2 SBC con mixer Art 4888 4888C 11 10 11 settaggio in SB2 o SBC H Tempo di attivazione rel sull interfaccia 9n 4 0 e 9 98 tempo 8 sec I L...

Page 4: ...will switch directly to Follow me mode while the telephone rings you will also be able to answer using any door entry phone monitor or telephone When you answer using the telephone in Follow me mode...

Page 5: ...setting to SB1 G Set to Simplebus 2 or SBC manually mixer Art 4888 4888C 11 10 11 setting to SB2 or SBC H Relay time on the interface 9n 4 0 en 9 98 time to 8 sec I The interface does not send ack aft...

Page 6: ...XT RIEUR L installateur peut configurer un autre mode de fonction Suivi Dans ce cas l interface ira directement dans la modalit Suivi alors que le t l phone sonnera galement et il sera possible de r p...

Page 7: ...ogrammer SB2 SBC H Temps d ouverture du relais sur l interface 9n 4 0 et 9 98 8 sec I l ack avis de r ception apr s un appel 20 21 20 utiliser lorsque l Art 2904 se trouve avant un commutateur Art 122...

Page 8: ...deurtelefoon een monitor of een telefoon kan worden geantwoord Als u de telefoon opneemt die door de volg mij functie is bereikt hoort u om de 3 seconden 3 pieptonen Als u op toets 1 drukt kunt u met...

Page 9: ...ixer Art 4888 4888C 11 10 11 instellen SB2 of SBC H Openingstijd van het relais op de interface 9n 4 0 en 9 98 tijd op 8 sec I De inferface verzendt geen ack bericht na een oproep 20 21 20 te gebruike...

Page 10: ...nehmen Nehmen Sie mit dem Telefon einen umgeleiteten Ruf an so h ren Sie 3 Signalt ne im Abstand von 3 Sekunden Durch Dr cken von Taste 1 k nnen Sie die Sprechverbindung mit dem Besucher herstellen dr...

Page 11: ...4888 4888C 10 10 10 Einstellen SB1 G Simplebus 2 SBC Manuel einstellen Mit Mixer Art 4888 4888C 11 10 11 Einstellen SB2 SBC H ffnungszeit Schnittstelle Relais 9n 4 0 e 9 98 Zeit auf 8 sec I Die Schnit...

Page 12: ...l tel fono y ser posible responder mediante un telefonillo un monitor o un tel fono Cuando se responde del tel fono al cual se ha transferido la llamada mediante la funci n S gueme se oir n tres bips...

Page 13: ...guraci n en SB1 G Configuraci n manual en Simplebus 2 SBC con mixer art 4888 4888C 11 10 11 configuraci n en SB2 o SBC H Tiempo de activaci n del rel en la interfaz 9n 4 0 y 9 98 tiempo 8 s I La inter...

Page 14: ...interface ficar directamente no modo Siga me enquanto tocar tamb m o telefone e ser poss vel responder atrav s de um telefone intercomunicador um monitor ou um telefone Quando se responde do telefone...

Page 15: ...grama o manual em Simplebus 2 SBC com misturador art 4888 4888C 11 10 11 programa o em SB2 ou SBC H Tempo de activa o do rel na interface 9n 4 0 e 9 98 tempo 8 seg I A interface n o envia o reconhecim...

Page 16: ...button Sist me audio Simplebus 1 avec interface Art 2904 Bouton commande ouvre porte local Simplebus 1 audio systeem met interface Art 2904 Bedieningsknop lokale deuropener Simplebus 1 Audio System mi...

Page 17: ...t me audio vid o Simplebus 2 avec interface Art 2904 Bouton commande ouvre porte local Simplebus 2 audio video systeem met interface Art 2904 Bedieningsknop lokale deuropener Simplebus 2 Audio Video S...

Page 18: ...t me audio vid o Simplebus SBC avec interface Art 2904 Bouton commande ouvre porte local Simplebus SBC audio video systeem met interface Art 2904 Bedieningsknop lokale deuropener Simplebus SBC Audio V...

Page 19: ...FT CT 05 FT CT 05 19...

Page 20: ...12 Erkelenz Tel 49 0 243190151 23 49 0 243190151 24 Fax 49 0 24319015125 www comelit de info comelit de Comelit Sud S r l Via Napoli 159 Centro Meridiana Torre Antares 80013 Casalnuovo di Napoli Na Te...

Reviews: