Comelit 6741W Technical Manual Download Page 2

2

Description ....................................................................................... 3

Touch-sensitive buttons ................................................................. 4

Description ...............................................................................................4
Indicator LED ............................................................................................4

Technical specifications ................................................................. 5

Installation ........................................................................................ 6

Addressing table ......................................................................................6
Building mode, Kit mode  ........................................................................7

Introduction .........................................................................................7
Configuration ......................................................................................7

Main and secondary door entry monitors .............................................8
Power Management .................................................................................8
Surface mounting .....................................................................................9

Removing the door entry monitor ..............................................10
Removing / fitting the terminal ..................................................10

Connections ............................................................................................11
Press and hold buttons ..........................................................................11

Button configuration  .............................................................................12

Configuration using the DIP-switches ..............................................12

Standard configurations ............................................................12
Advanced configuration.............................................................13

Configuration via the menu ...............................................................18

WiFree device operation ........................................................................18

Create the commands to be associated with the buttons ................19

Operating third-party devices with functions that can be activated via 
URL ..........................................................................................................20
Changing the ringtone ...........................................................................21
Programming reset ................................................................................21

System performance and layouts ................................................ 22

Diagrams for systems with art. 8451V or 8451V/BM...........................22
Diagrams for systems with power supply unit art. 1210 or 1210A ....27
System diagrams with power supply unit art. 4888C / 4888CU .........30

System performance and layouts ................................................ 35

Contents

Warning

•  This Comelit product has been designed and manufactured for use in the creation of audio and video communication 

systems in residential, commercial, industrial and public buildings.

•  All activities connected to the installation of Comelit products must be carried out by qualified technical personnel, 

with careful observation of the indications provided in the manuals / instruction sheets supplied with those products.

•  Disconnect the power supply before carrying out any operations on the wiring.
•  Use wires with a cross-section suited to the distances involved, observing the instructions provided in the system 

manual.

•  We advise against running the system wires through the same duct as power cables (230V or higher).
•  To ensure Comelit products are used safely: carefully observe the indications provided in the manuals / instruction 

sheets; make sure the system created using Comelit products has not been tampered with / damaged.

•  Comelit products do not require maintenance aside from routine cleaning, which should be carried out in accordance 

with the indications provided in the manuals /instruction sheets. Any repairs must be carried out: for the products 

themselves, exclusively by 

Comelit Group S.p.A.

, for the systems, by qualified technical personnel.

• 

Comelit Group S.p.A.

 accepts no liability for any purpose other than the intended use, or failure to observe the 

indications and warnings contained in this manual / instruction sheet. 

Comelit Group S.p.A.

 reserves the right to 

change the information provided in this manual / instruction sheet at any time and without prior notice.

•  The manufacturer,

Comelit Group S.p.A.

, hereby declares that the radio equipment used in art. 6741W and art. 

6741W/BM conforms to directive 2014/53/EU. The full EU conformity declarations are available at the following web 

addresses: pro.comelitgroup.com/it-it/prodotto/6741w and pro.comelitgroup.com/it-it/prodotto/6741w-bm

Summary of Contents for 6741W

Page 1: ...COMELIT L APP PER IL PROFESSIONISTA Amazon Alexa and all related logos are trademarks of Amazon com Inc or its affiliates EN TECHNICAL MANUAL Mini Hands Free Wi Fi Door Entry Monitor Art 6741W Art 674...

Page 2: ...rovided in the manuals instruction sheets supplied with those products Disconnect the power supply before carrying out any operations on the wiring Use wires with a cross section suited to the distanc...

Page 3: ...onry work Art 6741W is supplied with a mounting backplate and riser distribution terminal art 1214 2C Art 6741W BM is equipped with a magnetic induction audio amplification system and does not come wi...

Page 4: ...l from the external entrance panel and the switchboard and an intercom call not programmable Arrow keys Confirm selection Message menu Pressing and holding enables disables the function see Press and...

Page 5: ...OLS Type of Wi Fi connection IEEE 802 11 b g n 2 4 Ghz 13 channels IEEE 802 11 b g n 2 4 Ghz 13 channels Encryption method and supported authentication Networks OPEN WPA PSK TKIP WPA2 PSK AES WEP 64 b...

Page 6: ...5 6 7 125 1 3 4 5 6 7 126 2 3 4 5 6 7 127 1 2 3 4 5 6 7 128 8 129 1 8 130 2 8 131 1 2 8 132 3 8 133 1 3 8 134 2 3 8 135 1 2 3 8 136 4 8 137 1 4 8 138 2 4 8 139 1 2 4 8 140 3 4 8 141 1 3 4 8 142 2 3 4...

Page 7: ...refore need to be set in Building mode Kit mode is possible in systems powered by art 1209 with a maximum of 16 internal units in total for up to 4 x 6741W BM units Kit mode is possible in systems pow...

Page 8: ...power supply management set DIP 7 S2 according to the table With art 6741W with a revision index RR greater than or equal to 12 and with art 6741W BM with a revision index RR greater than or equal to...

Page 9: ...y monitor and the construction materials used in the walls are factors that can affect signal quality If the Wi Fi signal is not strong enough to guarantee correct operation a Wi Fi repeater must be i...

Page 10: ...10 6 2 1 5 3 1 2 L L C F P 1 C F P 2 1 2 3 Removing fitting the terminal 3 4 1 2 Removing the door entry monitor BACK...

Page 11: ...ton on one only all the devices will ring simultaneously Press and hold buttons disabled by default from firmware version 2 0 0 Pressing and holding the buttons adds functions to the door entry monito...

Page 12: ...ttons on page 11 From firmware version 2 1 0 onwards the door entry monitor button configuration can be changed in 2 different ways using S2 DIP switches 1 2 3 4 via the door entry monitor menu Config...

Page 13: ...ercom call This is an intercom call to groups of several internal units in the same apartment or another apartment identified by a dedicated intercom call code different from the code identifying the...

Page 14: ...8 The same intercom call code can be associated with up to 3 devices Now proceed as follows 2 Make a note of the S1 DIP switch settings 3 To enter programming mode set S2 DIP 6 to ON the LED flashes...

Page 15: ...Correct procedure indication the LED flashes for a few seconds and a confirmation tone sounds 5 Exit programming mode by setting S2 DIP 6 to OFF LED switches off S2 6 Set S2 DIP switches 1 2 3 4 to O...

Page 16: ...8 Return the S1 DIP switch to its original combination Other functions Button configuration 1 To enter programming mode set S2 DIP 6 to ON the LED flashes S2 2 Refer to the table Standard configurati...

Page 17: ...de in accordance with the Addressing table on page 6 S2 S2 Configuring the maximum range address 1 2 3 4 S1 set a code in accordance with the Addressing table on page 6 S2 S2 Deleting the range 1 2 3...

Page 18: ...1 Set the door entry monitor to Kit mode by moving S3 DIP switch 1 on the rear of the door entry monitor to ON as shown in the figure ON ON 1 2 S3 2 Set S2 DIP switches 1 2 3 4 on the rear of the door...

Page 19: ...to be associated Different direct links can be created for each WiFree device in the system based on the type of command you want to implement Access the Supla portal via the Comelit WiFree app 1 2 3...

Page 20: ...ON 1 2 3 4 6 7 5 8 S2 1 Set S2 DIP switches 1 2 3 4 on the rear of the door entry monitor to ON as shown in the figure 2 From the door entry monitor display Press the menu button select Setup and conf...

Page 21: ...e the floor door call ringtone Any further pressing of the button repeats the sequence described above 3 Press and release to scroll through the available ringtones in sequence 4 Press to confirm sele...

Page 22: ...ble secondary door entry monitors art 6601W 6601W BM 6701W 6701W BM 6701W 8 6721W 6721W BM 6801W 6801W BM A max B max Comelit Art 4577 4579 1 mm2 1 2 mm AWG 17 200 m 655 feet 100 m 330 feet UTP5 cat 5...

Page 23: ...button Two family system C F P L L C F P 1 2 L L O D E T R NO SE SE NC C M O C 1209 L N 110 240V L2 L2 L1 L1 4893M 6741W 6741W BM 6710 ON S1 1 2 3 4 6 7 5 8 ON S2 1 2 3 4 6 7 5 8 ON S1 1 2 3 4 6 7 5 8...

Page 24: ...M LM OUT L IN L IN L OUT L LM LM OUT L IN L IN L OUT L C F P L L C F P 1 2 6721W 6721W BM 6710 1214 2C 1214 2C L L 1216 C F P L L C F P 1 2 ON S1 1 2 3 4 6 7 5 8 ON S2 1 2 3 4 6 7 5 8 ON S1 1 2 3 4 6...

Page 25: ...MAX MIN LP OUT A B JP1 Kit 8451V 8451V BM L N 110 240V L2 L2 L1 L1 L N 110 240V L2 L2 L1 L1 1209 ON S3 1 2 3 4 SECONDARY MAIN Local door opener button Single family system with 2 external entrance pan...

Page 26: ...A B JP1 1404 L M L M L S L S LP IN LP OUT L L O D E T R NO SE SE NC C M O C L N L2 L2 L1 L1 1209 L L O D E T R NO SE SE NC C M O C 1209 L N L2 L2 L1 L1 110 240V 110 240V 110 240V 4893M 4893M ON 1 2 3...

Page 27: ...A 6741W 6741W BM 6710 6741W 6741W BM 6710 ON S3 1 2 ON S3 1 2 max 3 door entry monitors or 1229A max 1 door entry monitor or 1229A KIT MODE BUILDING MODE Compatible secondary door entry monitors 6601W...

Page 28: ...C F P L L C F P 1 2 IN 1 2 IN 6801W BM 1214 2C L OUT L IN L IN L OUT LM LM 2738W 2738W A 6710 6741W 6741W BM 6710 1210A L N 230V L2 L2 L1 L1 UT2020 UT9200 MAX 8 E T R GND SE SE NO NC C O M L L V V 67...

Page 29: ...L M L S L S LP IN LP OUT A B JP1 ON S1 MIN 1 2 3 4 6 7 5 8 ON S2 MAX 1 2 3 4 6 7 5 8 ON S3 1 2 3 4 L N 230V L2 L2 L1 L1 E T R GND SE SE NO NC C O M L L V V 1210A L N 230V L2 L2 L1 L1 UT2020 UT9200 MA...

Page 30: ...patible secondary door entry monitors art 6601W 6601W BM 6701W 6701W BM 6701W 8 6721W 6721W BM 6801W 6801W BM A max B max F max H max Comelit Art 4577 4579 1 mm2 1 2 mm AWG 17 200 m 655 feet 200 m 655...

Page 31: ...all repetition devices with the same user code 4 4 3 4 1 Maximum no of main door entry monitors that can be powered via riser 2 2 2 2 1 Maximum no of main door entry monitors that can be powered by ar...

Page 32: ...C F P 1 2 6721W 6721W BM 6710 6741W 6741W BM 6710 IN 2 1 IN 2 1 P F C L L P F C S S 6601W 6601W BM L OUT L IN L IN L OUT 1214 2C LM LM L L C F P C F P 2738W 2738W A L L 1216 LM LM LM LM E T R GND SE...

Page 33: ...N MIN 1 2 3 4 6 7 5 8 ON MAX 1 2 3 4 6 7 5 8 UT1020 UT9200 UT1020 UT9200 Video entry riser Local door opener button 20 m max Variant for porter switchboard connection 4888C 1 L IN L IN L 4 L 3 L 2 L 1...

Page 34: ...ND SE NO NC C O M L L V V 120 230 V E T R GND SE NO NC C O M L L V V 120 230 V E T R GND SE NO NC C O M L L V V 120 230 V 1595 1595 1595 Video entry riser Local door opener button 20 m max Art 6741W B...

Page 35: ...7 5 8 ON S1 1 2 3 4 6 7 5 8 ON S2 8 MAIN Compatible secondary door entry monitors art 6601W 6601W BM 6701W 6701W BM 6701W 8 6721W 6721W BM 6801W 6801W BM System performance and layouts For further in...

Page 36: ...4th edition 03 2022 code 2G40002878 w w w c o m e l i t g r o u p c o m Via Don Arrigoni 5 24020 Rovetta BG Italy C E R T I F I E D M A N A G E M E N T S Y S T E M S...

Reviews: