15
9.
Return the S1 DIP-switch settings to their original combination.
If you need to delete the intercom call code, proceed as follows:
1.
2.
3.
Take note of the
S1, S2 settings and
restore them when
programming
is
complete.
Se the
DIP-switches
as shown in the figure.
S1
S2
x4
x10
OK prog:
KO prog:
x4
x10
OK prog:
KO prog:
Two-family intercom call: button configuration
The button for the Two-family intercom call function can also be programmed using the procedure described in the section
“Configuration via the menu” on page 18
.
1.
Take note of the S1 DIP-switch settings.
2.
To enter programming mode, set S2 DIP 6 to ON.
» the LED
flashes
S2
3.
Refer to the table
to identify a DIP-switch 1-2-3-4 combination in which the intercom
function (INTb) corresponding to the button you want to program appears, then set the
S2
DIP-switches.
Example: For button 1= Two-family intercom (INTb), set S2 DIP-switches 1-2-3-4 as specified in row "H" in the
table
4.
Press and release the button to be associated with the function.
» Correct procedure indication: the LED
flashes for a few seconds and a confirmation tone sounds.
5.
Exit programming mode by setting S2 DIP 6 to OFF.
» LED
switches off
S2
6.
Set S2
DIP-switches 1-2-3-4
to ON.
7.
Return the S1 DIP-switch settings to their original combination.
Configuring actuator control
The door entry monitor keys can be configured to activate one or more actuators within the system.
Generic actuator: button configuration
The button for the Generic actuator function can also be programmed using the procedure described in the section
“Configuration via the menu” on page 18
.
1.
Take note of the S1 DIP-switch settings.
2.
To enter programming mode, set S2
DIP
6
to ON.
» the LED
flashes
S2
3.
Refer to the table
to identify a DIP-switch 1-2-3-4 combination
in which the actuator function (ACT) corresponding to the button you want to program
appears, then set the
S2
DIP-switches.
Example: For button X= Actuator (ACT), set S2 DIP-switches 1-2-3-4 as specified in row "E"
in the table
Example
S2
4.
Set all S1 DIP-switches to ON.
S1
5.
Press and release the button to be associated with the function.
» Correct procedure indication: the LED
flashes for a few seconds and a confirmation tone sounds.
< BACK