12
Button configuration
By default the buttons are configured with the functions shown in the table:
AP
ACT
AI
CCS
D
Legend
AP
Lock-release
Press and release key
ACT
Actuator
AI
**
Self activation
CAMG
Remote camera module with generic address
CAM1
Remote camera module with address 220
CAM2
Remote camera module with address 221
CCP
*
Call to main switchboard
CCS
*
Call to secondary switchboard
K
Caretaker door-entry phone call
PAN
*
Panic
INT
General or selective intercom.
Default: single-family call
INTb
Two-family intercom call
-
for Kit only
NULL
No function
D
**
Door opening upon call (Doctor) mode
Press and hold key
PROG
Programmed functions, see
In this DIP-switch setting, the buttons control the programmed
functions; the NON-programmed buttons control the functions referred to on line A (default)
.
*
Cannot be used in Kit systems
**
Pressing and holding enables / disables the function
, see
“Press and hold buttons” on page 11
From firmware version 2.1.0 onwards, the door entry monitor button configuration can be changed in 2 different ways:
- using S2 DIP-switches 1-2-3-4
- via the door entry monitor menu
Configuration using the DIP-switches
It is possible to change the default configuration of the buttons by changing the positions of the S2 DIP-switches 1-2-3-4 on the
rear of the door entry monitor to one of the combinations (B-P) suggested in the table below. All the buttons will change function.
Standard configurations
S2
Dip-switches
Art. 6741W (/BM)
DIP 1
DIP 2
DIP 3
DIP 4
default
A
OFF
OFF
OFF
OFF
AP
ACT
AI
CCS
D
B
ON
OFF
OFF
OFF
AP
CCS
AI
INT
INTb
C
OFF
ON
OFF
OFF
AP
INT
AI
INTb
ACT
D
ON
ON
OFF
OFF
AP
ACT
CCS
CCP
PAN
E
OFF
OFF
ON
OFF
ACT
ACT
ACT
ACT
ACT
F
ON
OFF
ON
OFF
AP
INT
ACT
CCS
CCP
G
OFF
ON
ON
OFF
AP
AI
D
K
CCS
H
ON
ON
ON
OFF
AP
INTb
INT
AI
INT
I
OFF
OFF
OFF
ON
AP
CCS
PAN
D
AI
J
ON
OFF
OFF
ON
AP
K
CCS
PAN
CCP
K
OFF
ON
OFF
ON
AP
CCP
K
PAN
ACT
L
ON
ON
OFF
ON
AP
AI
CAMG
CAM1
CAM2
M
OFF
OFF
ON
ON
AP
INTb
AI
INT
ACT
N
ON
OFF
ON
ON
AP
INT
INT
INT
INT
P
OFF
ON
ON
ON
NULL
NULL
NULL
NULL
NULL
ON
ON
ON
ON
PROG
< BACK