Switchboard electrical speci
fi
cations
Rated supply voltage
230V~ ± 10% - 50Hz ± 10% 25VA
Consumption from mains 230V~
(power supply unit, switchboard and battery only)
0,3 A
Switchboard PSU output voltage
13.8V DC ± 5% 1.5A max.
Battery predisposition
12V 7Ah max.
Operating temperature
+5°C to +40°C, RH max 90%
Tamper detection circuit
Double balance, closed on termination - 1800 ohm (2 resistors)
Switchboard current consumption @13.8V DC,
with message module and IP module active but not connected and GSM module not in
transmission
180mA
Keypad current consumption @13.8V DC,
1) LEDs and LCD OFF 2) LEDs and LCD ON
1) 30mA
2) 70mA
Keypad current consumption with RFID reader @13.8V DC,
1) LEDs and LCD OFF 2) LEDs and LCD ON
1) 35mA
2) 75mA
I/O expansion module current consumption in standby @13.8V DC
25mA
Bus RFID reader current consumption @13.8V DC 1) in standby, 2) LEDs ON
3) reading / writing
1) 19mA
2) 24mA
3) 45 / 55mA
Bus radio receiver current consumption @13.8V DC
1) idle 2) idle and LEDs ON 3) reading key and LEDs ON
1) 12mA
2) 18mA
3) 45mA - 55mA max
Value of end-of-line resistors in double balance
1800 ohm (2 resistors per circuit)
Value of end-of-line resistors in triple balance (e.g. alarm + fault)
1800 ohm (2 resistors per circuit, plus one 3300 ohm resistor)
RS485 cable connection
V+ BUS (Power supply positive)
V- (Power supply negative)
A (Data bus signal A)
B (Data bus signal B)
Maximum length of data cable
1000m
Relay output
1 potential-free exchange, 3A @ 24VDC
TC outputs
Con
fi
gurable as OC or OE, limited to 100mA
Setting the control panel to Service Status
Exiting Service Status
This function allows the installer to work on the VEDO System with complete peace of mind, with the siren, PSTN part, GSM part and
email all “silenced”.
The control panel is working and can be programmed (via Safe Manager) but does not generate any Alarm event.
1. From the keypad, enter a valid user code (default 111111)
2. Press Prog
3. The
fi
rst line of the display will show the message “System, Mgmt.” indicating that you can now modify the system options
4. Using the navigation keys (up and down), select the “COMMANDS” menu on the second line of the display, and press Con
fi
rm: the message
“GENERATE COMMAND” will appear on the
fi
rst line of the display
5. Using the navigation keys (up and down), select “AUTH. INSTALLER?” on the second line, and press Con
fi
rm: the message “DONE” will
appear on the display
6. Press C until you have exited the menus completely (i.e. until the date and time are displayed on the keypad)
7. Enter a valid user code (default 111111) or a valid installer code (default Master code 001961).
8. Press Prog
9. Open the control panel cover
10. Insert jumper JP7
1. Remove jumper JP7.
2. Enter a valid user code (default 111111) or a valid installer code (default Master code 001961).
3. Press Prog
4. Close the control panel cover
5. Press C until you have exited the menus completely
»
The control panel will remain in service while jumper JP7 remains inserted. The keypad display will show "SCHEDULED MAINTENANCE!" or
"N" across all areas.