22
Addressing and speed con
fi
guration of Planux Manager bus
Like any other device connected to the 485 bus, the Minitouch must also respond to a single address. This can be con
fi
gured by programming
the Planux Manager from its display.
If there is no bus signal (e.g. if the power is ON but the 485 bus is not connected):
•
A pop-up appears on the display prompting you to con
fi
gure the device address and bus speed. If the device has already been con
fi
gured,
you do not need to do anything
•
If the device still needs to be con
fi
gured, or if the existing con
fi
guration needs to be changed, select Device Address
•
Enter the desired address number and con
fi
rm, then
•
Select Bus Speed: the possible options will appear, one of which will be active
•
Select the desired speed, then select Exit.
For more detailed information about con
fi
guring Planux Manager, refer to the speci
fi
c Planux Manager instructions.
Guidance on the installation of Safetouch, Minitouch and Planux Manager
Safetouch/Minitouch
Safetouch/Minitouch is intended for installation using the mountings of a standard, pre-installed type 503 box.
Preparation
: insert the tip of a slim screwdriver between the two slots on the right-hand side of the bezel to separate the mounting frame from
the electronics and display part.
Fixing
:
1. Using suitable fasteners for securing the frame to the mounting points of the 503 box on the wall,
fi
x the Safetouch/Minitouch frame to the type
503 box with screws, taking care not to damage the frame by overtightening the screws.
2. Once you have made the necessary connections, re
fi
t the display part to the frame,
fi
rst using the clips on the left-hand side and then exerting
slight pressure on the right-hand edge, to help join the remaining clips.
Planux Manager
For instructions on how to mount Planux Manager, see the speci
fi
c sheet supplied with the Planux Manager bracket.
Expansions on 485 bus
Expansion on bus with 8 balanceable inputs and 8 logic outputs on bus (art. 30003101)
Each input can be con
fi
gured as NC, NO, single, double and triple balance, double zone and double zone with termination.
Set to detect tampering if the housing is opened or the unit is removed from the wall.
Tampers can be disabled.
Planux Manager with RFID key reader (art. 20034801)
Planux Manager is the built-in supervisor for the range: as well as incorporating all the control features available on Minitouch, it performs
advanced, full-duplex video entry functions, with dedicated, programmable function keys. It does not have any alarm inputs or outputs.
Planux Manager terminal block description
Pin
Name
Function
1
+VS
Not used
2
D
Data Signal for home automation Simplebus
3
B
RS485 data bus - B
4
A
RS485 data bus - A
5
S-
Call repeater device connection
6
S+
Call repeater device connection
7
CFP
Floor door call input
8
CFP
Floor door call input
9
L
Video door entry bus line connection terminal
10
L
Video door entry bus line connection terminal
11
-
Power supply negative input, common to home automation bus and alarm bus
12
+
Power supply positive input
485 line termination
Planux Manager also offers the possibility of inserting an end-of-line resistor for the 485 communication part.
Name
Function
CV8
If activated, connects the line termination to the 485 bus line