background image

26

C2 - How to configure a main or secondary 

switchboard

1. 

press the 

MENU

 key and use the 

 keys to view the 

Configurations

 menu, press 

OK

14 :15 : 26

Mon 12 Mar 12

• Settings

• Configurations

• Directory

• Received calls

• Alarms

2. 

use the 

 keys to view the

 System

 menu, press 

OK

14 :15 : 26

Lun 12 Mar 12

• Sistema

• Servizi

3. 

use the 

 keys to view the

 System

 menu, press 

OK

14 :15 : 26

Mon 12 Mar 12

System 

         

Simplebus            

Link 

      

Single                  

  

Call 

     

 

Simplebus             

A/V 

      

Audio                    

Backwards com.    

    

 

          

Esc 

 

             Ok

4. 

press 

OK

 to confirm the settings;

 

f

press 

ESC 

repeatedly to return to the main screen.

C3 - How to configure a switchboard as single, parallel 

or series

1. 

press the 

MENU

 key and use the 

 keys to view the 

Configurations

 menu, press 

OK

14 :15 : 26

Mon 12 Mar 12

• Settings

• Configurations

• Directory

• Received calls

• Alarms

2. 

use the 

 keys to view the 

System

 menu, press 

OK

14 :15 : 26

Mon 12 Mar 12

• System

• Services

3. 

use the 

 keys to view the 

Link

 menu, press 

OK

14 :15 : 26

Mon 12 Mar 12

System 

       

Simplebus         

 

Link   

     Single                 

Call 

     

Simplebus          

A/V 

       

Audio                 

 

Backwards com.    

     

 

          

Esc 

 

             Ok

4. 

select 

Single, Parall. LS-IN, Parall. LP-IN, Master in 

series, Slave in series

 using the 

 keys.

5. 

press 

OK

 to confirm the settings;

 

f

press

 ESC

 repeatedly to return to the main screen.

C4 - Call via Simplebus or indirect code

This function can be used to select the manual switchboard 

calling mode, from the 2 options available:

1.  Simplebus call (default)

, the call is made by entering the 

code corresponding to each user. 

 

»

If the system is a 

Simplebus 

type, the door-entry 

phone user is identified by a User Name field (optional) 

and a Code field no longer than 3 digits (between 1 

and 240)  

EXAMPLE:

 User name = Smith; Code = 015.

 

»

If using a 

Simplebus top

 system, the door-entry 

phone user is identified by the User Name field 

(optional) and a Code field consisting of 2 parts, a 

zone field with up to 3 digits (between 1 and 500) and 

a user field which must have 3 digits (between 1 and 

240). 

EXAMPLE: 

User name = Smith; Code = 25 015.

2.  Indirect call

, the call is made by entering the indirect 

code, which should have a maximum of 6 digits. This 

code must be stored in the memory and associated with 

the user who has been given a name (compulsory) and 

Simplebus (or Simplebus TOP code).

To activate the function:

1. 

press the 

MENU

 key and use the 

 keys to view the 

Configurations 

menu, press 

OK

14 :15 : 26

Mon 12 Mar 12
• Settings

• Configurations

• Directory

• Received calls

• Alarms

2. 

use the 

 keys to view the

 System

 menu, press 

OK

14 :15 : 26

Mon 12 Mar 12
• System

• Services

3. 

 use the 

 keys to view the 

Call

 menu, press 

OK

Summary of Contents for 1998VC

Page 1: ...EN TECHNICAL MANUAL Porter switchboard Art 1998VC Passion Technology Design...

Page 2: ...s the power cables 230V or higher Safe usage To ensure Comelit products are used safely carefully observe the indications provided in the Manuals Instruction sheets make sure the system created using...

Page 3: ...dditional relay e g to activate independently using a specific command lights CCTV alarm contacts vehicle barriers entrances without an external unit or other devices 13 U15 How to use the directory 1...

Page 4: ...r enable external monitor LM LM Data line to risers LP1 LP2 Incoming data line from external unit GND TX RX RS232 serial port for connection to the remote switchboard in systems with multiple switchbo...

Page 5: ...ing indicates malfunctioning of the serial line 10 LM flashing indicates a short circuit on the riser line the text is accompanied by a tone which sounds repeatedly The switchboard rejects any attempt...

Page 6: ...ch could not be answered are stored a DIRECTORY which can be programmed so as to identify the caller easily Technical features MAIN FEATURES Height mm 130 Width mm 200 Depth mm 223 Operating temperatu...

Page 7: ...L UNIT 1998VC 1195 1 2 1 2 0 2 3 0 0 2 4 LP 1 24 0 L M L M C H C H LP 2 O U T O U T T X R X G N D C NO RS 232 FOR DOWNLOADING NAMES IN DIRECTORY VIA 1249 A Free contact for CALL REP or ENABLE EXTERNAL...

Page 8: ...mode in NIGHT mode it will only answer direct switchboard calls The switchboard can receive a call from an external unit addressed directly to an internal unit in which case the NAME of the called un...

Page 9: ...n is equal to the audio time set on the main switchboard MENU Settings Timers Audio min 10 seconds max 90 seconds U4 How to transfer a call from the external unit to an internal unit When the switchbo...

Page 10: ...ith internal unit 003 and press to resume communication with internal unit 002 14 15 26 Lun 12 Mar 12 In comunicazione con 002 f f to end the conversation hang up the handset CAUTION If the external u...

Page 11: ...e call has not taken place correctly 14 15 26 Mon 12 Mar 12 User not available if the system is busy 14 15 26 Mon 12 Mar 12 Line busy When the handset of the switchboard called is lifted it communicat...

Page 12: ...hboard 14 15 26 Mon 12 Mar 12 Switchboard call f f to answer the call coming from the main switchboard lift the handset f f to end the conversation hang up the handset CAUTION If the switchboard is bu...

Page 13: ...nu press OK 14 15 26 Mon 12 Mar 12 Settings Configurations Directory Received calls Alarms 2 use the keys to view the Services menu press OK 14 15 26 Mon 12 Mar 12 System Services 3 use the keys to vi...

Page 14: ...Mar 12 ________________________ Sergio Rossi Code 012 Scroll Menu Or f f enter the name even using just part of the extension If there are several users with the same initial you can scroll through t...

Page 15: ...nu Or 1 enter the name even using just part of the extension If there are several users with the same initial you can scroll through the list using the keys 14 15 26 Mon 12 Mar 12 ____________________...

Page 16: ...te all Info a screen will appear asking if you wish to delete the entire directory confirm using OK or cancel using ESC Delete All Ok Esc f f press ESC repeatedly to return to the main screen U21 Dire...

Page 17: ...Mar 12 Settings Configurations Directory Received calls Alarms 2 use the keys to view the View entry press OK 14 15 26 Mon 12 Mar 12 View Delete all the calls received and made are displayed in chron...

Page 18: ...ry press OK 14 15 26 Mon 12 Mar 12 View Delete all the calls are displayed in chronological order beginning with the most recent call received use the keys to scroll through the list To speed up scrol...

Page 19: ...larm Alarm 1 Key tone Date Year 2010 Month Marzo Day 12 Time Hours 14 Minutes 15 Seconds 26 Daily mode Enable Sun Night Mon Night Tue Night Wed Night Thur Night Fri Night Sat Night Skins Reset setting...

Page 20: ...ations Directory Received calls Alarms 2 use the keys to view the Video menu press OK 14 15 26 Mon 12 Mar 12 Language Video Audio Tones Date 3 use the keys to view the video setting you wish to adjust...

Page 21: ...5 26 Mon 12 Mar 12 External Spring Internal Spring Alarm Alarm 1 Key tone Esc Ok 4 select the melody using the keys 5 Activate the Tone service using the key Disable it using 6 press OK to confirm the...

Page 22: ...ress OK 14 15 26 Mon 12 Mar 12 Tones Date Time Skins Timers 3 use the keys to view the setting you wish to adjust audio reset wait time standby relay activation call repeat and decrease or increase th...

Page 23: ...3 00 22 00 Day mode operation 14 15 26 Mon 12 Mar 12 Swt1 07 00 Day Swt2 12 00 Night Swt3 13 00 Day Swt4 22 00 Night Esc Ok 1 press the MENU key and use the keys to view the Settings menu press OK 14...

Page 24: ...2 Mar 12 Skins Timers Daily mode Automatic switching Reset settings 3 a screen will appear asking if you wish to reset the settings confirm using OK or cancel using ESC 14 15 26 Mon 12 Mar 12 Timers M...

Page 25: ...he LS LS line of switching device Art 1424 as Parall LS IN set the switchboard located under the LPin LPin line of switching device Art 1424 as Parall LP IN For the parallel switchboard switching to N...

Page 26: ...ESC repeatedly to return to the main screen C4 Call via Simplebus or indirect code This function can be used to select the manual switchboard calling mode from the 2 options available 1 Simplebus cal...

Page 27: ...calling will allow you to make a video call to an internal unit The monitor called by the switchboard will switch on making it possible to view for example the images from the remote cameras connected...

Page 28: ...is function can be used to activate or deactivate the triple call made by the switchboard to the internal units The call will therefore take place on consecutive occasions in the case of video calls t...

Page 29: ...w w w c o m e l i t g r o u p c o m Via Don Arrigoni 5 24020 Rovetta BG Italy 2 nd edition 06 2019 cod 2G40002109 C E R T I F I E D M A N A G E M E N T S Y S T E M S...

Reviews: