7
Pin 4: Power enable
Enables the output oscillator with an external contact
closure between pins 4 and 9 (24 VOLTS, 0.5 AMPS
MAX SWITCHING)
Pin 9: Power enable
Common for Pin 4
Pin 11: Safety interlock
Enables the input A/C power contactor with an external
contact closure to Pin 12. (24 VOLTS, 0.5 AMPS MAX
SWITCHING).
Pin 12: Safety interlock common.
Pin 6: Signal common
Pin 7: Power on indicator
+5 VDC source when RF Power is on
Pin 8: Power on common
Common for Pin 7
D. Mechanical Specifications
1. Size: 17" W x 5.25" H x 16.125" D max.
2. Mounting: Standard 19" rack.
3.
Cooling: 1.5 G.P.M. MIN, 35 degrees C MAX 25% glycol mix MAX
4. Water connections: 1/4 NPT female, inlet and outlet.
5. Front panel indicators:
5.1 Power meters: Dual meters to indicate forward and reverse power.
5.2 Power on indicators: Visible green LED to indicate A/C power on.
5.3 Fault indication: Visible red LED to indicate temp fault.
6. Handles: Two handles (left and right) to be mounted on the front panel exterior, evenly
spaced on center, dimensioned
7. Color: Front panel to be black with contrasting white alpha/numeric designators.
8. Warning Labels:
8.1 Safety Labels for hazardous voltages, Heavy Object, and Caution for lifting by
water fittings are to be provided on operator visible areas of the generator. IEC
standard symbols in user visible areas for start, stop, enable and cautionary
conditions, PE ground, high temperatures and RF energy present.
8.2 Special marking available at customers specifications
E. Environmental Specifications
1. Operating Temperature & Humidity
1.1 Operating ambient temperature/humidity/air pressure: 10 to 40
°
C, 5 - 85%
humidity (non-condensing, no formation of ice), 86-106 kPa. Class 3k3 per
prEN50178.