9
www.combisteel.com
•
The service life of oil will depends on the working condition and an environment with clean and dry air. Normally the oil
must need changing every 50 working hours or at least every 6 months.
•
Please check the level and volume of oil in pump once at least per week. User can check the oil volume via oil window,
if the oil level is lower than the position of 1/2 that showing from oil indicator, then it must need filling oil.
Seal Strip
Please check the seal rubber at least once per week. If the seal strip is broken or not even enough, please replace it
immediately.
•
The seal strip is stuck in the groove of the lid, it can be moved out directly.
•
Remove the old seal strip from the groove of the lid.
•
Install a new seal strip into the groove.
•
After finish installation, please check if the seal strip is installed evenly or not.
Gasket
The purpose of gasket is to make the chamber under sealed condition when the machine is working. It is important for the
machine to reach required vacuum pressure. Due to under different pressure, the gasket will be worn. So, it must be replaced
periodically. The gasket need checking once per week at least, checking it if it is worn or broken.
•
The gasket is stuck in the groove of the lid, it can be moved out directly.
•
User can check the length of new gasket according to the old one, if the gasket is too long or too short, it may cause the
lid cannot be closed tight or leaving some gap to cause any leakage when machine is working.
•
Install a new gasket into the groove.
•
Please make sure the gasket is installed evenly but not over tight. Both ends of gasket must be installed perfectly straight
and evenly and compactly to avoid any leakage.
Errors and troubleshooting
Error code Causes of warning
Troubleshooting
E01
When the machine is vacuuming for
some time, the pressure switch doesn’t
close.
1)
Check if the lid is closed tight.
2)
Check if the gate control switch system is working normally
or not (like gate control switch assy, GASI connecting cord,
micro switch, 10P data cord)
LP
Machine loses power during the
working
1)
check the power supply.
2)
check the power supply system of machine (power cord,
10P data cord).
The A-weighted sound pressure level is 73.9dB(A). The vibration level is 0.34m/s2
Thank you for purchasing the Vacuum Sealer.
Happy Vacuuming!